Normal Brain and Brain Tumor ADC: Changes Resulting From Variation of Diffusion Time And/or Echo Time in Pulsed-Gradient Spin Echo Diffusion Imaging

Overview
Journal Invest Radiol
Specialty Radiology
Date 2024 Apr 8
PMID 38587357
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Increasing gradient performance on modern magnetic resonance imaging scanners has profoundly reduced the attainable diffusion and echo times for clinically available pulsed-gradient spin echo (PGSE) sequences. This study investigated how this may impact the measured apparent diffusion coefficient (ADC), which is considered an important diagnostic marker for differentiation between normal and abnormal brain tissue and for therapeutic follow-up.

Materials And Methods: Diffusion time and echo time dependence of the ADC were evaluated on a high-performance 3 T magnetic resonance imaging scanner. Diffusion PGSE brain scans were performed in 10 healthy volunteers and in 10 brain tumor patients using diffusion times of 16, 40, and 70 ms, echo times of 60, 75, and 104 ms at 3 b-values (0, 100, and 1000 s/mm 2 ), and a maximum gradient amplitude of 68 mT/m. A low gradient performance system was also emulated by reducing the diffusion encoding gradient amplitude to 19 mT/m. In healthy subjects, the ADC was measured in 6 deep gray matter regions and in 6 white matter regions. In patients, the ADC was measured in the solid part of the tumor.

Results: With increasing diffusion time, a small but significant ADC increase of up to 2.5% was observed for 6 aggregate deep gray matter structures. With increasing echo time or reduced gradient performance, a small but significant ADC decrease of up to 2.6% was observed for 6 aggregate white matter structures. In tumors, diffusion time-related ADC changes were inconsistent without clear trend. For tumors with diffusivity above 1.0 μm 2 /ms, with prolonged echo time, there was a pronounced ADC increase of up to 12%. Meanwhile, for tumors with diffusivity at or below 1.0 μm 2 /ms, no change or a reduction was observed. Similar results were observed for gradient performance reduction, with an increase of up to 21%. The coefficient of variation determined in repeat experiments was 2.4%.

Conclusions: For PGSE and the explored parameter range, normal tissue ADC changes seem negligible. Meanwhile, observed tumor ADC changes can be relevant if ADC is used as a quantitative biomarker and not merely assessed by visual inspection. This highlights the importance of reporting all pertinent timing parameters in ADC studies and of considering these effects when building scan protocols for use in multicenter investigations.

Citing Articles

Comparison of SS-EPI DWI and one-minute TGSE-BLADE DWI for diagnosis of acute infarction.

Okuchi S, Fushimi Y, Sakata A, Otani S, Nakajima S, Maki T Sci Rep. 2025; 15(1):6512.

PMID: 39987155 PMC: 11846894. DOI: 10.1038/s41598-025-90413-5.

References
1.
Drake-Perez M, Boto J, Fitsiori A, Lovblad K, Vargas M . Clinical applications of diffusion weighted imaging in neuroradiology. Insights Imaging. 2018; 9(4):535-547. PMC: 6108979. DOI: 10.1007/s13244-018-0624-3. View

2.
Zhang H, Liu K, Ba R, Zhang Z, Zhang Y, Chen Y . Histological and molecular classifications of pediatric glioma with time-dependent diffusion MRI-based microstructural mapping. Neuro Oncol. 2023; 25(6):1146-1156. PMC: 10237431. DOI: 10.1093/neuonc/noad003. View

3.
Baron C, Beaulieu C . Oscillating gradient spin-echo (OGSE) diffusion tensor imaging of the human brain. Magn Reson Med. 2013; 72(3):726-36. DOI: 10.1002/mrm.24987. View

4.
Teruel J, Cho G, Moccaldi Rt M, Goa P, Bathen T, Feiweier T . Stimulated echo diffusion tensor imaging (STEAM-DTI) with varying diffusion times as a probe of breast tissue. J Magn Reson Imaging. 2016; 45(1):84-93. DOI: 10.1002/jmri.25376. View

5.
Qin W, Yu C, Zhang F, Du X, Jiang H, Yan Y . Effects of echo time on diffusion quantification of brain white matter at 1.5 T and 3.0 T. Magn Reson Med. 2009; 61(4):755-60. DOI: 10.1002/mrm.21920. View