Abstract

Purpose: Quantitative fundus autofluorescence (QAF) currently deploys an age-based score to correct for lens opacification. However, in elderly people, lens opacification varies strongly between individuals of similar age, and innate lens autofluorescence is not included in the current correction formula. Our goal was to develop and compare an individualized formula.

Methods: One hundred thirty participants were examined cross-sectionally, and a subset of 30 participants received additional multimodal imaging 2-week post-cataract-surgery. Imaging included the Scheimpflug principle, anterior chamber optical coherence tomography (AC-OCT), lens quantitative autofluorescence (LQAF), and retinal QAF imaging. Among the subset, least absolute shrinkage and selection operator regression and backward selection was implemented to determine which lens score best predicts the QAF value after lens extraction. Subsequently, a spline mixed model was applied to the whole cohort to quantify the influence of LQAF and Scheimpflug on QAF.

Results: Age and LQAF measurements were found to be the most relevant variables, whereas AC-OCT measurements and Scheimpflug were eliminated by backward selection. Both an increase in Scheimpflug and LQAF values were associated with a decrease in QAF. The prediction error of the spline model (mean absolute error [MAE] ± standard deviation) of 32.2 ± 23.4 (QAF a.u.) was markedly lower compared to the current age-based formula MAE of 96.1 ± 93.5. Both smooth terms, LQAF (P < 0.01) and Scheimpflug (P < 0.001), were significant for the spline mixed model.

Conclusions: LQAF imaging proved to be the most predictive for the impact of the natural lens on QAF imaging. The application of lens scores in the clinic could improve the accuracy of QAF imaging interpretation and might allow including aged patients in future QAF studies.

Citing Articles

Quantitative autofluorescence is increased in clinically unaffected fellow eyes from patients with posterior uveitis.

Finger R, Jungblut J, Just M, Terheyden J, Holz F, Liegl R Sci Rep. 2025; 15(1):6952.

PMID: 40011481 PMC: 11865583. DOI: 10.1038/s41598-025-90071-7.


Fundus Autofluorescence Variation in Geographic Atrophy of Age-Related Macular Degeneration: A Clinicopathologic Correlation.

Curcio C, Messinger J, Berlin A, Sloan K, McLeod D, Edwards M Invest Ophthalmol Vis Sci. 2025; 66(1):49.

PMID: 39836402 PMC: 11756612. DOI: 10.1167/iovs.66.1.49.


Impact of lens autofluorescence and opacification on retinal imaging.

von der Emde L, Rennen G, Vaisband M, Hasenauer J, Liegl R, Fleckenstein M BMJ Open Ophthalmol. 2024; 9(1).

PMID: 38684375 PMC: 11086461. DOI: 10.1136/bmjophth-2023-001628.


Personalized Lens Correction Improves Quantitative Fundus Autofluorescence Analysis.

von der Emde L, Rennen G, Vaisband M, Hasenauer J, Liegl R, Fleckenstein M Invest Ophthalmol Vis Sci. 2024; 65(3):13.

PMID: 38466288 PMC: 10929741. DOI: 10.1167/iovs.65.3.13.

References
1.
Artigas J, Felipe A, Navea A, Fandino A, Artigas C . Spectral transmission of the human crystalline lens in adult and elderly persons: color and total transmission of visible light. Invest Ophthalmol Vis Sci. 2012; 53(7):4076-84. DOI: 10.1167/iovs.12-9471. View

2.
Fleckenstein M, Keenan T, Guymer R, Chakravarthy U, Schmitz-Valckenberg S, Klaver C . Age-related macular degeneration. Nat Rev Dis Primers. 2021; 7(1):31. DOI: 10.1038/s41572-021-00265-2. View

3.
Van Best J, Kuppens E . Summary of studies on the blue-green autofluorescence and light transmission of the ocular lens. J Biomed Opt. 2012; 1(3):243-50. DOI: 10.1117/12.241531. View

4.
Gliem M, Muller P, Finger R, McGuinness M, Holz F, Charbel Issa P . Quantitative Fundus Autofluorescence in Early and Intermediate Age-Related Macular Degeneration. JAMA Ophthalmol. 2016; 134(7):817-24. DOI: 10.1001/jamaophthalmol.2016.1475. View

5.
Schindelin J, Arganda-Carreras I, Frise E, Kaynig V, Longair M, Pietzsch T . Fiji: an open-source platform for biological-image analysis. Nat Methods. 2012; 9(7):676-82. PMC: 3855844. DOI: 10.1038/nmeth.2019. View