Introduction: Home-based self-collected dried blood spot (DBS) sampling could simplify sexual health and preexposure prophylaxis care and reduce sexually transmitted infections (STIs) clinic visits for men who have sex with men (MSM). We compared the performance of DBS to venipuncture collected blood samples to test four STIs and creatinine concentration.

Methods: We invited MSM clients of the Amsterdam STI clinic to participate. Routinely collected peripheral blood was tested for syphilis treponemal antibody, HIV (HIV Ag/Ab), HCV (antibodies), HBV (HBsAg) and creatinine concentration. Participants received a home kit for DBS sampling, a return envelope and a questionnaire to evaluate the acceptability, feasibility and usability of DBS, measured on 5-point Likert scales, 1 representing complete disagreement and 5 complete agreement. We assessed sensitivity and specificity of DBS versus peripheral blood-based testing.

Results: In 2020 to 2021, we included 410 participants; 211 (51.5%) returned a completed DBS card, 117 (28.5%) returned a partially filled card and 82 (20.0%) did not return a card. The sensitivity for syphilis was 90.8% and the specificity 84.3%. For both HIV Ag/Ab and HBsAg, the sensitivity and specificity were 100.0%. The sensitivity for HCV antibody was 80.0%, and the specificity was 99.2%. The DBS creatinine concentration was a mean of 5.3 μmol/L higher than in venipuncture obtained plasma. Participants' median willingness to take a future DBS was 4 (interquartile range, 3-5).

Discussion: Dried blood spot may be an acceptable method among MSM for STI testing and creatinine follow-up during preexposure prophylaxis use. However, collecting enough blood on DBS cards was a challenge, and sensitivities for syphilis and HCV serology were too low.

Citing Articles

Influence of Hematocrit and Storage Temperature on the Stability of Dried Blood Samples in Serological Analyses of Tetanus, Diphtheria, and Pertussis.

Rodriguez-Mateos M, Carlos S, Jaso J, Holguin A, Reina G Diagnostics (Basel). 2024; 14(19).

PMID: 39410599 PMC: 11475551. DOI: 10.3390/diagnostics14192195.

References
1.
Yared N, Horvath K, Fashanu O, Zhao R, Baker J, Kulasingam S . Optimizing Screening for Sexually Transmitted Infections in Men Using Self-Collected Swabs: A Systematic Review. Sex Transm Dis. 2018; 45(5):294-300. PMC: 5889342. DOI: 10.1097/OLQ.0000000000000739. View

2.
Mathew B, Mathew S, Aruldhas B, Prabha R, Gangadharan N, David V . Analytical and clinical validation of dried blood spot and volumetric absorptive microsampling for measurement of tacrolimus and creatinine after renal transplantation. Clin Biochem. 2022; 105-106:25-34. DOI: 10.1016/j.clinbiochem.2022.04.014. View

3.
den Daas C, Doppen M, Schmidt A, de Coul E . Determinants of never having tested for HIV among MSM in the Netherlands. BMJ Open. 2016; 6(1):e009480. PMC: 4716195. DOI: 10.1136/bmjopen-2015-009480. View

4.
Sullivan T, Antonio-Gaddy M, Richardson-Moore A, Styer L, Bigelow-Saulsbery D, Parker M . Expansion of HIV screening to non-clinical venues is aided by the use of dried blood spots for Western blot confirmation. J Clin Virol. 2013; 58 Suppl 1:e123-6. DOI: 10.1016/j.jcv.2013.08.004. View

5.
Bilic-Zulle L . Comparison of methods: Passing and Bablok regression. Biochem Med (Zagreb). 2011; 21(1):49-52. DOI: 10.11613/bm.2011.010. View