» Articles » PMID: 38393403

Utilizing Fully-automated 3D Organ Segmentation for Hepatic Steatosis Assessment with CT Attenuation-based Parameters

Overview
Journal Eur Radiol
Specialty Radiology
Date 2024 Feb 23
PMID 38393403
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: To investigate the clinical utility of fully-automated 3D organ segmentation in assessing hepatic steatosis on pre-contrast and post-contrast CT images using magnetic resonance spectroscopy (MRS)-proton density fat fraction (PDFF) as reference standard.

Materials And Methods: This retrospective study analyzed 362 adult potential living liver donors with abdominal CT scans and MRS-PDFF. Using a deep learning-based tool, mean volumetric CT attenuation of the liver and spleen were measured on pre-contrast (liver(L)_pre and spleen(S)_pre) and post-contrast (L_post and S_post) images. Agreements between volumetric and manual region-of-interest (ROI)-based measurements were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performances of volumetric parameters (L_pre, liver-minus-spleen (L-S)_pre, L_post, and L-S_post) were evaluated for detecting MRS-PDFF ≥ 5% and ≥ 10% using receiver operating characteristic (ROC) curve analysis and compared with those of ROI-based parameters.

Results: Among the 362 subjects, 105 and 35 had hepatic steatosis with MRS-PDFF ≥ 5% and ≥ 10%, respectively. Volumetric and ROI-based measurements revealed ICCs of 0.974, 0.825, 0.992, and 0.962, with mean differences of -4.2 HU, -3.4 HU, -1.2 HU, and -7.7 HU for L_pre, S_pre, L_post, and S_post, respectively. Volumetric L_pre, L-S_pre, L_post, and L-S_post yielded areas under the ROC curve of 0.813, 0.813, 0.734, and 0.817 for MRS-PDFF ≥ 5%; and 0.901, 0.915, 0.818, and 0.868 for MRS-PDFF ≥ 10%, comparable with those of ROI-based parameters (0.735-0.818; and 0.816-0.895, Ps = 0.228-0.911).

Conclusion: Automated 3D segmentation of the liver and spleen in CT scans can provide volumetric CT attenuation-based parameters to detect and grade hepatic steatosis, applicable to pre-contrast and post-contrast images.

Clinical Relevance Statement: Volumetric CT attenuation-based parameters of the liver and spleen, obtained through automated segmentation tools from pre-contrast or post-contrast CT scans, can efficiently detect and grade hepatic steatosis, making them applicable for large population data collection.

Key Points: • Automated organ segmentation enables the extraction of CT attenuation-based parameters for the target organ. • Volumetric liver and spleen CT attenuation-based parameters are highly accurate in hepatic steatosis assessment. • Automated CT measurements from pre- or post-contrast imaging show promise for hepatic steatosis screening in large cohorts.

Citing Articles

Diagnostic of fatty liver using radiomics and deep learning models on non-contrast abdominal CT.

Zhang H, Liu J, Su D, Bai Z, Wu Y, Ma Y PLoS One. 2025; 20(2):e0310938.

PMID: 39946425 PMC: 11825062. DOI: 10.1371/journal.pone.0310938.

References
1.
Nogami A, Yoneda M, Iwaki M, Kobayashi T, Honda Y, Ogawa Y . Non-invasive imaging biomarkers for liver steatosis in non-alcoholic fatty liver disease: present and future. Clin Mol Hepatol. 2022; 29(Suppl):S123-S135. PMC: 10029939. DOI: 10.3350/cmh.2022.0357. View

2.
Starekova J, Hernando D, Pickhardt P, Reeder S . Quantification of Liver Fat Content with CT and MRI: State of the Art. Radiology. 2021; 301(2):250-262. PMC: 8574059. DOI: 10.1148/radiol.2021204288. View

3.
Park S, Kwon J, Kim S, Kang J, Chung J, Jang J . Cutoff Values for Diagnosing Hepatic Steatosis Using Contemporary MRI-Proton Density Fat Fraction Measuring Methods. Korean J Radiol. 2022; 23(12):1260-1268. PMC: 9747271. DOI: 10.3348/kjr.2022.0334. View

4.
Bannas P, Kramer H, Hernando D, Agni R, Cunningham A, Mandal R . Quantitative magnetic resonance imaging of hepatic steatosis: Validation in ex vivo human livers. Hepatology. 2015; 62(5):1444-55. PMC: 4652324. DOI: 10.1002/hep.28012. View

5.
Ferraioli G, Kumar V, Ozturk A, Nam K, de Korte C, Barr R . US Attenuation for Liver Fat Quantification: An AIUM-RSNA QIBA Pulse-Echo Quantitative Ultrasound Initiative. Radiology. 2022; 302(3):495-506. DOI: 10.1148/radiol.210736. View