Evaluation of Fused Deposition Modeling Materials for 3D-Printed Container of Dosimetric Polymer Gel

Overview
Journal Gels
Date 2024 Feb 23
PMID 38391476
Authors
Affiliations
Soon will be listed here.
Abstract

Accurate dosimetric verification is becoming increasingly important in radiotherapy. Although polymer gel dosimetry may be useful for verifying complex 3D dose distributions, it has limitations for clinical application due to its strong reactivity with oxygen and other contaminants. Therefore, it is important that the material of the gel storage container blocks reaction with external contaminants. In this study, we tested the effect of air and the chemical permeability of various polymer-based 3D printing materials that can be used as gel containers. A methacrylic acid, gelatin, and tetrakis (hydroxymethyl) phosphonium chloride gel was used. Five types of printing materials that can be applied to the fused deposition modeling (FDM)-type 3D printer were compared: acrylonitrile butadiene styrene (ABS), co-polyester (CPE), polycarbonate (PC), polylactic acid (PLA), and polypropylene (PP) (reference: glass vial). The map of R2 (1/T2) relaxation rates for each material, obtained from magnetic resonance imaging scans, was analyzed. Additionally, response histograms and dose calibration curves from the R2 map were evaluated. The R2 distribution showed that CPE had sharper boundaries than the other materials, and the profile gradient of CPE was also closest to the reference vial. Histograms and dose calibration showed that CPE provided the most homogeneous and the highest relative response of 83.5%, with 8.6% root mean square error, compared with the reference vial. These results indicate that CPE is a reasonable material for the FDM-type 3D printing gel container.

References
1.
Baldock C, De Deene Y, Doran S, Ibbott G, Jirasek A, Lepage M . Polymer gel dosimetry. Phys Med Biol. 2010; 55(5):R1-63. PMC: 3031873. DOI: 10.1088/0031-9155/55/5/R01. View

2.
Shim J, Kim J, Jeong S, Choi Y, Ryu J . Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations. J Prosthet Dent. 2019; 124(4):468-475. DOI: 10.1016/j.prosdent.2019.05.034. View

3.
Macchione M, Lechon Paez S, Strumia M, Valente M, Mattea F . Chemical Overview of Gel Dosimetry Systems: A Comprehensive Review. Gels. 2022; 8(10). PMC: 9601373. DOI: 10.3390/gels8100663. View

4.
Farhood B, Geraily G, Abtahi S . A systematic review of clinical applications of polymer gel dosimeters in radiotherapy. Appl Radiat Isot. 2018; 143:47-59. DOI: 10.1016/j.apradiso.2018.08.018. View

5.
De Deene Y, De Wagter C . Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: III. Effects of temperature drift during scanning. Phys Med Biol. 2001; 46(10):2697-711. DOI: 10.1088/0031-9155/46/10/312. View