» Articles » PMID: 38381265

Cutting Efficiency and Corrosion Resistance of Heat-treated Endodontic Files After Various Disinfection Protocols

Overview
Journal Odontology
Specialty Dentistry
Date 2024 Feb 21
PMID 38381265
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study is to evaluate the effect of various disinfection protocols on the cutting efficiency and chemical composition of ProTaper, Twisted File, Twisted File Adaptive, and Hedström files. Four experimental groups (n = 10) were presoaked in either enzymatic solution or 1% sodium hypochlorite for 30 min, followed by either 5 or 15 min of ultrasonic cleaning and then autoclaved. Resin-simulated canals with a single curvature of 38-40° were prepared by each instrument system. Cutting efficiency of each instrument was analyzed by subtracting the final weight from the initial weight of the resin blocks. Chemical compositions were studied by field emission scanning electron microscopy and X-ray energy-dispersive spectrometry. The cutting efficiency of Hedström, ProTaper, and Twisted File instruments decreased compared to their control groups (p < 0.05) whereas it did not change for Twisted File Adaptive. More corrosion was detected with longer ultrasonication time. No difference was observed regarding the pre-soaking media. Disinfection protocols exerted a significant overall effect on the performance of Hedström, ProTaper, and Twisted File instruments. Corrosion, microcracks, and crevices were evident on all tested instruments after disinfection protocols applied. All disinfection protocols, regardless of the pre-soaking media used or the ultrasonic cleaning time applied, have some effect on the cutting efficiency and the surface characteristics of the files.

Citing Articles

Effect of phytic acid on chemical, structural, and mechanical characteristics of nickel-titanium endodontic files.

Samara M, Nassar M, Alqedairi A, Alfawaz H, Jamleh A Sci Rep. 2024; 14(1):20164.

PMID: 39215062 PMC: 11364813. DOI: 10.1038/s41598-024-69828-z.

References
1.
Shuping G, Orstavik D, Sigurdsson A, Trope M . Reduction of intracanal bacteria using nickel-titanium rotary instrumentation and various medications. J Endod. 2001; 26(12):751-5. DOI: 10.1097/00004770-200012000-00022. View

2.
Linsuwanont P, Parashos P, Messer H . Cleaning of rotary nickel-titanium endodontic instruments. Int Endod J. 2004; 37(1):19-28. DOI: 10.1111/j.1365-2591.2004.00747.x. View

3.
Parashos P, Linsuwanont P, Messer H . A cleaning protocol for rotary nickel-titanium endodontic instruments. Aust Dent J. 2004; 49(1):20-7. DOI: 10.1111/j.1834-7819.2004.tb00045.x. View

4.
Keles A, Uzunoglu Ozyurek E, Uyanik M, Nagas E . Effect of Temperature of Sodium Hypochlorite on Cyclic Fatigue Resistance of Heat-treated Reciprocating Files. J Endod. 2019; 45(2):205-208. DOI: 10.1016/j.joen.2018.11.003. View

5.
Elnaghy A, Elsaka S . Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments. Int Endod J. 2016; 50(10):991-998. DOI: 10.1111/iej.12712. View