» Articles » PMID: 38362543

Feasibility of Leveraging Consumer Wearable Devices with Data Platform Integration for Patient Vital Monitoring in Low-Resource Settings

Abstract

Manual monitoring of vital signs, which often fails to capture the onset of deterioration, is the main monitoring modality in most Ghanaian hospitals due to the high cost and inadequate supply of patient bedside monitors. Consumer wearable devices (CWDs) are emerging, relatively low-cost technologies for continuous monitoring of physiological status; however, their validity has not been established in low-resource clinical settings. We aimed to (1) investigate the validity of the heart rate (HR) and oxygen saturation (SpO2) data from two widely used CWDs, the Fitbit Versa 2 and Xiaomi Mi Smart Band 6, against gold standard bedside monitors in one Ghanaian hospital and (2) develop a web application to capture and display CWD data in a clinician-friendly way. A healthy volunteer simultaneously wore both CWDs and blood pressure cuffs to measure HR and SpO2. To test for concordance, we conducted the Bland-Altman and mean absolute percentage error analyses. We also developed a web application that retrieves and displays CWD data in near real time as text and graphical trends. Compared to gold standards (patient monitor and manual), the Fitbit Versa 2 had 96.87% and 96.67% measurement accuracies for HR, and the Xiaomi Mi Smart Band 6 had 94.24% and 93.21% measurement accuracies for HR. The Xiaomi Mi Smart Band 6 had 98.79% measurement accuracy for SpO2. The strong concordance between CWD and gold standards supports the potential implementation of these devices as a novel method of vital sign monitoring to replace manual monitoring, thus saving costs and improving patient outcomes. Further studies are needed for confirmation.

References
1.
Wallen M, Gomersall S, Keating S, Wisloff U, Coombes J . Accuracy of Heart Rate Watches: Implications for Weight Management. PLoS One. 2016; 11(5):e0154420. PMC: 4883747. DOI: 10.1371/journal.pone.0154420. View

2.
Carter M, Linton S, Zeineddin S, Pitt J, Figueroa A, Perez A . Consumer Wearables Define a Normative Recovery Trajectory Following the Modified Nuss Procedure. J Surg Res. 2023; 292:7-13. DOI: 10.1016/j.jss.2023.07.002. View

3.
Schmidt P, Meredith P, Prytherch D, Watson D, Watson V, Killen R . Impact of introducing an electronic physiological surveillance system on hospital mortality. BMJ Qual Saf. 2014; 24(1):10-20. DOI: 10.1136/bmjqs-2014-003073. View

4.
Smith L, Banner L, Lozano D, Olney C, Friedman B . Connected care: reducing errors through automated vital signs data upload. Comput Inform Nurs. 2009; 27(5):318-23. DOI: 10.1097/NCN.0b013e3181b21d65. View

5.
Pitt J, Zeineddin S, Carter M, Figueroa A, Park E, Kwon S . Using Consumer Wearable Devices to Profile Postoperative Complications After Pediatric Appendectomy. J Surg Res. 2023; 295:853-861. DOI: 10.1016/j.jss.2023.08.060. View