» Articles » PMID: 19726926

Connected Care: Reducing Errors Through Automated Vital Signs Data Upload

Overview
Date 2009 Sep 4
PMID 19726926
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Vital signs are a fundamental component of patient care. Omitted or inaccurately transcribed vital sign data could result in inappropriate, delayed, or missed treatment. A previous baseline study determined that error rates for vital signs captured on plain paper then entered into a paper chart or EMR were 10% and 4.4%, respectively. This study evaluated the impact of automated vital signs captured using a PDA with bar-code technology for patient identification. The PDA enabled the wireless capture and transmission of data directly from the vital sign monitor into the EMR. Researchers reviewed 1514 sets of vital signs collected electronically for accuracy and compared the error rate with data from the previous paper and EMR systems. Automated upload of vital signs directly into an EMR reduced the documentation error rate to less than 1%. This represented a significant reduction in vital sign documentation errors with the use of mobile technology when compared with traditional charting methods (P < .001). The automated vital sign data upload system helped promote a culture of patient safety by greatly reducing documentation error rates. Additional safety benefits may include improved timeliness to vital sign data and clinical work-flow processes.

Citing Articles

Effectiveness of Remote Patient Monitoring Equipped With an Early Warning System in Tertiary Care Hospital Wards: Retrospective Cohort Study.

Lakshman P, Gopal P, Khurdi S J Med Internet Res. 2025; 27:e56463.

PMID: 39813676 PMC: 11780298. DOI: 10.2196/56463.


Feasibility of Leveraging Consumer Wearable Devices with Data Platform Integration for Patient Vital Monitoring in Low-Resource Settings.

Kaufmann E, Tackie R, Pitt J, Mba S, Akwetey B, Quaye D Int J Telemed Appl. 2024; 2024:8906413.

PMID: 38362543 PMC: 10869189. DOI: 10.1155/2024/8906413.


Automated documentation of vital parameters in wards using portable stations - Effect on proper triggering of the rapid response team: a study protocol of a cluster randomized clinical trial.

Ribeiro J, Sgorbissa C, Silva K, Braz M, Peneluppi Horak A, Nicola M Rev Bras Ter Intensiva. 2022; 34(3):319-326.

PMID: 36351064 PMC: 9749098. DOI: 10.5935/0103-507X.20220101-pt.


Development and Comparative Performance of Physiologic Monitoring Strategies in the Emergency Department.

Kim D, Jin B JAMA Netw Open. 2022; 5(9):e2233712.

PMID: 36169956 PMC: 9520367. DOI: 10.1001/jamanetworkopen.2022.33712.


A Theoretical Framework for Understanding Creator-Consumer Information Interaction Behaviors in Healthcare Documentation Systems.

Pennathur P Appl Ergon. 2020; 84:103034.

PMID: 31987517 PMC: 7141766. DOI: 10.1016/j.apergo.2019.103034.