Real-time Evaluation of Signal Accuracy in Wastewater Surveillance of Pathogens with High Rates of Mutation

Abstract

Wastewater surveillance of coronavirus disease 2019 (COVID-19) commonly applies reverse transcription-quantitative polymerase chain reaction (RT-qPCR) to quantify severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA concentrations in wastewater over time. In most applications worldwide, maximal sensitivity and specificity of RT-qPCR has been achieved, in part, by monitoring two or more genomic loci of SARS-CoV-2. In Ontario, Canada, the provincial Wastewater Surveillance Initiative reports the average copies of the CDC N1 and N2 loci normalized to the fecal biomarker pepper mild mottle virus. In November 2021, the emergence of the Omicron variant of concern, harboring a C28311T mutation within the CDC N1 probe region, challenged the accuracy of the consensus between the RT-qPCR measurements of the N1 and N2 loci of SARS-CoV-2. In this study, we developed and applied a novel real-time dual loci quality assurance and control framework based on the relative difference between the loci measurements to the City of Ottawa dataset to identify a loss of sensitivity of the N1 assay in the period from July 10, 2022 to January 31, 2023. Further analysis via sequencing and allele-specific RT-qPCR revealed a high proportion of mutations C28312T and A28330G during the study period, both in the City of Ottawa and across the province. It is hypothesized that nucleotide mutations in the probe region, especially A28330G, led to inefficient annealing, resulting in reduction in sensitivity and accuracy of the N1 assay. This study highlights the importance of implementing quality assurance and control criteria to continually evaluate, in near real-time, the accuracy of the signal produced in wastewater surveillance applications that rely on detection of pathogens whose genomes undergo high rates of mutation.

Citing Articles

The Crucial Role of Laboratory Medicine in Addressing Future Public Health Infectious Threats: Insights Gained from the COVID-19 Pandemic.

Lippi G, Henry B, Mattiuzzi C Diagnostics (Basel). 2025; 15(3).

PMID: 39941256 PMC: 11817188. DOI: 10.3390/diagnostics15030323.


Underestimation of SARS-CoV-2 in wastewater due to single or double mutations in the N1 qPCR probe binding region.

Sun J, Yang M, Peng J, Khan I, Lopez J, Chan R Water Res X. 2024; 22:100221.

PMID: 38590726 PMC: 11000202. DOI: 10.1016/j.wroa.2024.100221.

References
1.
Bivins A, Kaya D, Bibby K, Simpson S, Bustin S, Shanks O . Variability in RT-qPCR assay parameters indicates unreliable SARS-CoV-2 RNA quantification for wastewater surveillance. Water Res. 2021; 203:117516. PMC: 8341816. DOI: 10.1016/j.watres.2021.117516. View

2.
Shannon A, Selisko B, Le N, Huchting J, Touret F, Piorkowski G . Rapid incorporation of Favipiravir by the fast and permissive viral RNA polymerase complex results in SARS-CoV-2 lethal mutagenesis. Nat Commun. 2020; 11(1):4682. PMC: 7499305. DOI: 10.1038/s41467-020-18463-z. View

3.
Chen C, Nadeau S, Yared M, Voinov P, Xie N, Roemer C . CoV-Spectrum: analysis of globally shared SARS-CoV-2 data to identify and characterize new variants. Bioinformatics. 2021; 38(6):1735-1737. PMC: 8896605. DOI: 10.1093/bioinformatics/btab856. View

4.
Justo Arevalo S, Zapata Sifuentes D, Huallpa C, Landa Bianchi G, Castillo Chavez A, Garavito-Salini Casas R . Dynamics of SARS-CoV-2 mutations reveals regional-specificity and similar trends of N501 and high-frequency mutation N501Y in different levels of control measures. Sci Rep. 2021; 11(1):17755. PMC: 8423746. DOI: 10.1038/s41598-021-97267-7. View

5.
Silva C, Tryndyak V, Camacho L, Orloff M, Porter A, Garner K . Temporal dynamics of SARS-CoV-2 genome and detection of variants of concern in wastewater influent from two metropolitan areas in Arkansas. Sci Total Environ. 2022; 849:157546. PMC: 9338166. DOI: 10.1016/j.scitotenv.2022.157546. View