Short-Term Outcomes of XEN45 Standalone Versus Combined with Phacoemulsification in Open-Angle Glaucoma Patients: A Retrospective Study

Overview
Journal J Clin Med
Specialty General Medicine
Date 2024 Jan 11
PMID 38202164
Authors
Affiliations
Soon will be listed here.
Abstract

The XEN45 is a minimally invasive glaucoma surgery device commonly used in clinical practice. This retrospective study included consecutive patients with open-angle glaucoma who underwent a XEN45 implant with mitomycin C, either alone or in combination with phacoemulsification, between June 2015 and March 2021. The primary end point was the mean change in intraocular pressure (IOP) from the baseline to month 6. A total of 677 eyes, 395 (58.3%) in the XEN alone group and 282 (41.7%) in the XEN+Phaco group, were included in this study. The preoperative IOP was significantly lowered from 28.7 ± 8.6 mmHg and 25.4 ± 6.9 mmHg to 13.5 ± 5.0 mmHg and 13.5 ± 4.1 mmHg at month 6 in the XEN solo and XEN+Phaco groups, respectively, with < 0.0001 each. The mean (95% confidence interval) number of ocular hypotensive medications was significantly reduced from 3.3 (3.2-3.4) to 0.2 (0.1-0.2) and from 3.1 (2.9-3.2) to 0.2 (0.1-0.2) in the XEN solo and XEN+Phaco groups, respectively, with < 0.0001 each. Needling was performed in 228 (33.7%) eyes. Conclusions: the XEN implant significantly reduces both IOP and the number of ocular hypotensive medications. IOP lowering was higher in the XEN solo group than in the XEN+Phaco one, although such a difference was only evident during the first month after surgery.

Citing Articles

No Changes in Keratometry Readings and Anterior Chamber Depth after XEN Gel Implantation in Patients with Glaucoma.

Tatti F, Tronci C, Lixi F, Demarinis G, Kuzmich S, Peiretti E J Clin Med. 2024; 13(9).

PMID: 38731065 PMC: 11084149. DOI: 10.3390/jcm13092537.

References
1.
Zhang J, Murgoitio-Esandi J, Qian X, Li R, Gong C, Nankali A . High-Frequency Ultrasound Elastography to Assess the Nonlinear Elastic Properties of the Cornea and Ciliary Body. IEEE Trans Ultrason Ferroelectr Freq Control. 2022; 69(9):2621-2629. PMC: 9547080. DOI: 10.1109/TUFFC.2022.3190400. View

2.
Laborda-Guirao T, Cubero-Parra J, Hidalgo-Torres A . Efficacy and safety of XEN 45 gel stent alone or in combination with phacoemulsification in advanced open angle glaucoma patients: 1-year retrospective study. Int J Ophthalmol. 2020; 13(8):1250-1256. PMC: 7387914. DOI: 10.18240/ijo.2020.08.11. View

3.
Panarelli J, Yan D, Francis B, Craven E . XEN Gel Stent Open Conjunctiva Technique: A Practical Approach Paper. Adv Ther. 2020; 37(5):2538-2549. PMC: 7467501. DOI: 10.1007/s12325-020-01278-1. View

4.
Schlenker M, Gulamhusein H, Conrad-Hengerer I, Somers A, Lenzhofer M, Stalmans I . Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy. Ophthalmology. 2017; 124(11):1579-1588. DOI: 10.1016/j.ophtha.2017.05.004. View

5.
Li R, Qian X, Gong C, Zhang J, Liu Y, Xu B . Simultaneous Assessment of the Whole Eye Biomechanics Using Ultrasonic Elastography. IEEE Trans Biomed Eng. 2022; 70(4):1310-1317. PMC: 10365545. DOI: 10.1109/TBME.2022.3215498. View