» Articles » PMID: 38059633

Visceral Adipose Tissue Volume Effect in Crohn's Disease Using Reduced Exposure CT Enterography

Overview
Date 2023 Dec 7
PMID 38059633
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence.

Methods: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity.

Results: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure).

Conclusions: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.

Citing Articles

Visceral adipose tissue volume effect in Crohn's disease using reduced exposure CT enterography.

Hunter S, Baker M, Ream J, Sweet D, Austin N, Remer E J Appl Clin Med Phys. 2023; 25(1):e14235.

PMID: 38059633 PMC: 10795447. DOI: 10.1002/acm2.14235.

References
1.
Kambadakone A, Chaudhary N, Desai G, Nguyen D, Kulkarni N, Sahani D . Low-dose MDCT and CT enterography of patients with Crohn disease: feasibility of adaptive statistical iterative reconstruction. AJR Am J Roentgenol. 2011; 196(6):W743-52. DOI: 10.2214/AJR.10.5303. View

2.
Gordic S, Desbiolles L, Sedlmair M, Manka R, Plass A, Schmidt B . Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography. Eur Radiol. 2015; 26(2):459-68. DOI: 10.1007/s00330-015-3862-5. View

3.
Chen S, Ma D, Su D, Li Y, Yu X, Jiang Y . The Optimal Axial Anatomical Site for a Single-Slice Area to Quantify the Total Volume of Visceral Adipose Tissue in Quantitative CT. Front Endocrinol (Lausanne). 2022; 13:870552. PMC: 9259943. DOI: 10.3389/fendo.2022.870552. View

4.
Al-Hawary M, Kaza R, Platt J . CT enterography: concepts and advances in Crohn's disease imaging. Radiol Clin North Am. 2012; 51(1):1-16. DOI: 10.1016/j.rcl.2012.09.001. View

5.
Desmond A, ORegan K, Curran C, McWilliams S, Fitzgerald T, Maher M . Crohn's disease: factors associated with exposure to high levels of diagnostic radiation. Gut. 2008; 57(11):1524-9. DOI: 10.1136/gut.2008.151415. View