» Articles » PMID: 37998163

Detection of Reverse Transcriptase LAMP-Amplified Nucleic Acid from Oropharyngeal Viral Swab Samples Using Biotinylated DNA Probes Through a Lateral Flow Assay

Overview
Specialty Biotechnology
Date 2023 Nov 24
PMID 37998163
Authors
Affiliations
Soon will be listed here.
Abstract

This study focuses on three key aspects: (a) crude throat swab samples in a viral transport medium (VTM) as templates for RT-LAMP reactions; (b) a biotinylated DNA probe with enhanced specificity for LFA readouts; and (c) a digital semi-quantification of LFA readouts. Throat swab samples from SARS-CoV-2 positive and negative patients were used in their crude (no cleaning or pre-treatment) forms for the RT-LAMP reaction. The samples were heat-inactivated but not treated for any kind of nucleic acid extraction or purification. The RT-LAMP (20 min processing time) product was read out by an LFA approach using two labels: FITC and biotin. FITC was enzymatically incorporated into the RT-LAMP amplicon with the LF-LAMP primer, and biotin was introduced using biotinylated DNA probes, specifically for the amplicon region after RT-LAMP amplification. This assay setup with biotinylated DNA probe-based LFA readouts of the RT-LAMP amplicon was 98.11% sensitive and 96.15% specific. The LFA result was further analysed by a smartphone-based IVD device, wherein the T-line intensity was recorded. The LFA T-line intensity was then correlated with the qRT-PCR Ct value of the positive swab samples. A digital semi-quantification of RT-LAMP-LFA was reported with a correlation coefficient of R = 0.702. The overall RT-LAMP-LFA assay time was recorded to be 35 min with a LoD of three RNA copies/µL (Ct-33). With these three advancements, the nucleic acid testing-point of care technique (NAT-POCT) is exemplified as a versatile biosensor platform with great potential and applicability for the detection of pathogens without the need for sample storage, transportation, or pre-processing.

Citing Articles

Rapid detection of SARS-CoV-2 RNA using a one-step fast multiplex RT-PCR coupled to lateral flow immunoassay.

Bel Hadj Ali I, Souguir H, Melliti M, Mohamed M, Ardhaoui M, Ayouni K BMC Infect Dis. 2024; 24(1):1417.

PMID: 39695471 PMC: 11653822. DOI: 10.1186/s12879-024-10296-1.


Development of a rapid LFA test based on direct RT-LAMP for diagnosis of SARS-CoV-2.

Sadeghi N, Shirazi N, Dehbashi M, Maleki B, Cho W, Hojati Z Pract Lab Med. 2024; 42:e00437.

PMID: 39553462 PMC: 11565418. DOI: 10.1016/j.plabm.2024.e00437.

References
1.
Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N . Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000; 28(12):E63. PMC: 102748. DOI: 10.1093/nar/28.12.e63. View

2.
Subsoontorn P, Lohitnavy M, Kongkaew C . The diagnostic accuracy of isothermal nucleic acid point-of-care tests for human coronaviruses: A systematic review and meta-analysis. Sci Rep. 2020; 10(1):22349. PMC: 7749114. DOI: 10.1038/s41598-020-79237-7. View

3.
Corman V, Landt O, Kaiser M, Molenkamp R, Meijer A, Chu D . Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill. 2020; 25(3). PMC: 6988269. DOI: 10.2807/1560-7917.ES.2020.25.3.2000045. View

4.
Ivanov A, Safenkova I, Zherdev A, Dzantiev B . Nucleic acid lateral flow assay with recombinase polymerase amplification: Solutions for highly sensitive detection of RNA virus. Talanta. 2020; 210:120616. DOI: 10.1016/j.talanta.2019.120616. View

5.
Menting S, Erhart A, Schallig H . Laboratory Evaluation of a SARS-CoV-2 RT-LAMP Test. Trop Med Infect Dis. 2023; 8(6). PMC: 10302189. DOI: 10.3390/tropicalmed8060320. View