» Articles » PMID: 36140431

Detection of SARS-CoV-2 Using Reverse Transcription Helicase Dependent Amplification and Reverse Transcription Loop-Mediated Amplification Combined with Lateral Flow Assay

Abstract

Rapid and accurate detection and identification of pathogens in clinical samples is essential for all infection diseases. However, in the case of epidemics, it plays a key role not only in the implementation of effective therapy but also in limiting the spread of the epidemic. In this study, we present the application of two nucleic acid isothermal amplification methods-reverse transcription helicase dependent amplification (RT-HDA) and reverse transcription loop-mediated amplification (RT-LAMP)-combined with lateral flow assay as the tools for the rapid detection of SARS-CoV-2, the etiological agent of COVID-19, which caused the ongoing global pandemic. In order to optimize the RT-had, the LOD was 3 genome copies per reaction for amplification conducted for 10-20 min, whereas for RT-LAMP, the LOD was 30-300 genome copies per reaction for a reaction conducted for 40 min. No false-positive results were detected for RT-HDA conducted for 10 to 90 min, but false-positive results occurred when RT-LAMP was conducted for longer than 40 min. We concluded that RT-HDA combined with LFA is more sensitive than RT-LAMP, and it is a good alternative for the development of point-of-care tests for SARS-CoV-2 detection as this method is simple, inexpensive, practical, and does not require qualified personnel to perform the test and interpret its results.

Citing Articles

Enhanced Specificity in Colorimetric LAMP Assay for Detection Using a Combination of Two Additives.

Wong Y, Hau P, Chau E, Ng L, Murillo M, Fung J J Fungi (Basel). 2024; 10(12).

PMID: 39728353 PMC: 11678401. DOI: 10.3390/jof10120857.


Current Trends in RNA Virus Detection via Nucleic Acid Isothermal Amplification-Based Platforms.

Ngoc L, Lee Y Biosensors (Basel). 2024; 14(2).

PMID: 38392016 PMC: 10886876. DOI: 10.3390/bios14020097.


Detection of Reverse Transcriptase LAMP-Amplified Nucleic Acid from Oropharyngeal Viral Swab Samples Using Biotinylated DNA Probes through a Lateral Flow Assay.

Agarwal S, Hamidizadeh M, Bier F Biosensors (Basel). 2023; 13(11).

PMID: 37998163 PMC: 10669123. DOI: 10.3390/bios13110988.


Detection of monkeypox virus using helicase dependent amplification and recombinase polymerase amplification combined with lateral flow test.

Gulinaizhaer A, Yang C, Zou M, Ma S, Fan X, Wu G Virol J. 2023; 20(1):274.

PMID: 37996921 PMC: 10668421. DOI: 10.1186/s12985-023-02223-8.


Recent Uses of Paper Microfluidics in Isothermal Nucleic Acid Amplification Tests.

Reynolds J, Loeffler R, Leigh P, Lopez H, Yoon J Biosensors (Basel). 2023; 13(9).

PMID: 37754119 PMC: 10526735. DOI: 10.3390/bios13090885.


References
1.
Wang R, Hozumi Y, Yin C, Wei G . Mutations on COVID-19 diagnostic targets. Genomics. 2020; 112(6):5204-5213. PMC: 7502284. DOI: 10.1016/j.ygeno.2020.09.028. View

2.
Sharma K, Sharma M, Batra N, Sharma A, Dhillon M . Diagnostic potential of multi-targeted LAMP (loop-mediated isothermal amplification) for osteoarticular tuberculosis. J Orthop Res. 2016; 35(2):361-365. DOI: 10.1002/jor.23293. View

3.
Lopez-Rincon A, Tonda A, Mendoza-Maldonado L, Mulders D, Molenkamp R, Perez-Romero C . Classification and specific primer design for accurate detection of SARS-CoV-2 using deep learning. Sci Rep. 2021; 11(1):947. PMC: 7806918. DOI: 10.1038/s41598-020-80363-5. View

4.
Mahalanabis M, Do J, Almuayad H, Zhang J, Klapperich C . Erratum to: An integrated disposable device for DNA extraction and helicase dependent amplification. Biomed Microdevices. 2011; 13(3):599-602. DOI: 10.1007/s10544-011-9518-6. View

5.
Rastawicki W, Rokosz-Chudziak N . Characteristics and assessment of the usefulness of serological tests in the diagnostic of infections caused by coronavirus SARS-CoV-2 on the basis of available manufacturer's data and literature review. Przegl Epidemiol. 2020; 74(1):49-68. DOI: 10.32394/pe.74.11. View