Purpose: The aim of this study was to investigate the performance of an artificial intelligence (AI)-based software for fully automated analysis of leg alignment pre- and postoperatively after high tibial osteotomy (HTO) on long-leg radiographs (LLRs).

Methods: Long-leg radiographs of 95 patients with varus malalignment that underwent medial open-wedge HTO were analyzed pre- and postoperatively. Three investigators and an AI software using deep learning algorithms (LAMA™, ImageBiopsy Lab, Vienna, Austria) evaluated the hip-knee-ankle angle (HKA), mechanical axis deviation (MAD), joint line convergence angle (JLCA), medial proximal tibial angle (MPTA), and mechanical lateral distal femoral angle (mLDFA). All measurements were performed twice and the performance of the AI software was compared with individual human readers using a Bayesian mixed model. In addition, the inter-observer intraclass correlation coefficient (ICC) for inter-observer reliability was evaluated by comparing measurements from manual readers. The intra-reader variability for manual measurements and the AI-based software was evaluated using the intra-observer ICC.

Results: Initial varus malalignment was corrected to slight valgus alignment after HTO. Measured by the AI algorithm and manually HKA (5.36° ± 3.03° and 5.47° ± 2.90° to - 0.70 ± 2.34 and - 0.54 ± 2.31), MAD (19.38 mm ± 11.39 mm and 20.17 mm ± 10.99 mm to - 2.68 ± 8.75 and - 2.10 ± 8.61) and MPTA (86.29° ± 2.42° and 86.08° ± 2.34° to 91.6 ± 3.0 and 91.81 ± 2.54) changed significantly from pre- to postoperative, while JLCA and mLDFA were not altered. The fully automated AI-based analyses showed no significant differences for all measurements compared with manual reads neither in native preoperative radiographs nor postoperatively after HTO. Mean absolute differences between the AI-based software and mean manual observer measurements were 0.5° or less for all measurements. Inter-observer ICCs for manual measurements were good to excellent for all measurements, except for JLCA, which showed moderate inter-observer ICCs. Intra-observer ICCs for manual measurements were excellent for all measurements, except for JLCA and for MPTA postoperatively. For the AI-aided analyses, repeated measurements showed entirely consistent results for all measurements with an intra-observer ICC of 1.0.

Conclusions: The AI-based software can provide fully automated analyses of native long-leg radiographs in patients with varus malalignment and after HTO with great accuracy and reproducibility and could support clinical workflows.

Level Of Evidence: Diagnostic study, Level III.

Citing Articles

Frontal plane mechanical leg alignment estimation from knee x-rays using deep learning.

Chen K, Stotter C, Lepenik C, Klestil T, Salzlechner C, Nehrer S Osteoarthr Cartil Open. 2025; 7(1):100551.

PMID: 39811691 PMC: 11729668. DOI: 10.1016/j.ocarto.2024.100551.


Evaluation of a deep learning software for automated measurements on full-leg standing radiographs.

Lassalle L, Regnard N, Durteste M, Ventre J, Marty V, Clovis L Knee Surg Relat Res. 2024; 36(1):40.

PMID: 39614404 PMC: 11606017. DOI: 10.1186/s43019-024-00246-1.


Automated Measurements of Long Leg Radiographs in Pediatric Patients: A Pilot Study to Evaluate an Artificial Intelligence-Based Algorithm.

van der Lelij T, Grootjans W, Braamhaar K, de Witte P Children (Basel). 2024; 11(10).

PMID: 39457148 PMC: 11505924. DOI: 10.3390/children11101182.


Joint line convergence angle is the most associated alignment factor with the severity of medial knee osteoarthritis.

Tsushima T, Sasaki E, Sakamoto Y, Kimura Y, Tsuda E, Ishibashi Y J Exp Orthop. 2024; 11(3):e70007.

PMID: 39176253 PMC: 11339597. DOI: 10.1002/jeo2.70007.


Artificial intelligence-based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta-analysis.

Salzmann M, Hassan Tarek H, Prill R, Becker R, Schreyer A, Hable R Knee Surg Sports Traumatol Arthrosc. 2024; 33(1):177-190.

PMID: 39033340 PMC: 11716349. DOI: 10.1002/ksa.12362.


References
1.
Minas T, von Keudell A, Bryant T, Gomoll A . The John Insall Award: A minimum 10-year outcome study of autologous chondrocyte implantation. Clin Orthop Relat Res. 2013; 472(1):41-51. PMC: 3889462. DOI: 10.1007/s11999-013-3146-9. View

2.
Pruneski J, Pareek A, Kunze K, Martin R, Karlsson J, Oeding J . Supervised machine learning and associated algorithms: applications in orthopedic surgery. Knee Surg Sports Traumatol Arthrosc. 2022; 31(4):1196-1202. DOI: 10.1007/s00167-022-07181-2. View

3.
Schock J, Truhn D, Abrar D, Merhof D, Conrad S, Post M . Automated Analysis of Alignment in Long-Leg Radiographs by Using a Fully Automated Support System Based on Artificial Intelligence. Radiol Artif Intell. 2021; 3(2):e200198. PMC: 8043357. DOI: 10.1148/ryai.2020200198. View

4.
Choi Y, Yu W, Nagarajan M, Teng P, Goldin J, Raman S . Translating AI to Clinical Practice: Overcoming Data Shift with Explainability. Radiographics. 2023; 43(5):e220105. PMC: 10190133. DOI: 10.1148/rg.220105. View

5.
Shin H, Han K, Ryu L, Kim E . The impact of artificial intelligence on the reading times of radiologists for chest radiographs. NPJ Digit Med. 2023; 6(1):82. PMC: 10148851. DOI: 10.1038/s41746-023-00829-4. View