» Articles » PMID: 37959552

Comparative Evaluation of the Digital Workflow and Conventional Method in Manufacturing Complete Removal Prostheses

Overview
Publisher MDPI
Date 2023 Nov 14
PMID 37959552
Authors
Affiliations
Soon will be listed here.
Abstract

The aging population in developed countries has increased the number of edentulous patients and, therefore, the need for prosthetic rehabilitation to improve their quality of life. Complete dentures are the main treatment option in these cases. The use of CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) in dentistry has improved clinical protocols and outcomes, achieving a reduction in work time and economic costs for the patients. The main objective of this review was to compare the characteristics of conventional and digital dentures, attempting to determine whether the use of new technologies represents an improvement in the properties of removable complete dentures. A bibliographic review was carried out in the PubMed/MEDLINE, Cochrane Library, Scielo, and Embase databases. With the initial search, 157 articles were obtained. After applying the inclusion and exclusion criteria, 64 publications were selected for this bibliographic review. The different conclusions of the studies consulted were compared regarding fit and retention, fracture resistance, surface roughness, biocompatibility, and aesthetics, taking into account the different methods of prostheses fabrication. In general, digital prostheses have shown better mechanical properties and, consequently, better biocompatibility and aesthetics than conventional prostheses. However, the obtained results were very heterogeneous, preventing a supported conclusion.

Citing Articles

Evaluation of Shear Bond Strength and Failure Modes of Lithium Disilicate Ceramic Veneering Material to Different High-Performance Polymers.

Alnafaiy S, Labban N, Albaijan R, AlKahtani R, Al-Aali K, Abozaed H Polymers (Basel). 2025; 17(5).

PMID: 40076048 PMC: 11901903. DOI: 10.3390/polym17050554.


3D-Printed Complete Dentures: A Review of Clinical and Patient-Based Outcomes.

Abdelnabi M, Swelem A Cureus. 2024; 16(9):e69698.

PMID: 39308835 PMC: 11415164. DOI: 10.7759/cureus.69698.

References
1.
Angelara K, Bratos M, Sorensen J . Comparison of strength of milled and conventionally processed PMMA complete-arch implant-supported immediate interim fixed dental prostheses. J Prosthet Dent. 2021; 129(1):221-227. DOI: 10.1016/j.prosdent.2021.04.025. View

2.
Alfadda S . The relationship between various parameters of complete denture quality and patients' satisfaction. J Am Dent Assoc. 2014; 145(9):941-8. DOI: 10.14219/jada.2013.48. View

3.
Faty M, Sabet M, Thabet Y . A Comparison of Denture Base Retention and Adaptation Between CAD/CAM and Conventional Fabrication Techniques. Int J Prosthodont. 2023; 36(4):469-478. DOI: 10.11607/ijp.7193. View

4.
Hsu C, Yang T, Wang T, Lin L . Effects of fabrication techniques on denture base adaptation: An in vitro study. J Prosthet Dent. 2020; 124(6):740-747. DOI: 10.1016/j.prosdent.2020.02.012. View

5.
Srinivasan M, Kalberer N, Kamnoedboon P, Mekki M, Durual S, Ozcan M . CAD-CAM complete denture resins: an evaluation of biocompatibility, mechanical properties, and surface characteristics. J Dent. 2021; 114:103785. DOI: 10.1016/j.jdent.2021.103785. View