» Articles » PMID: 29962017

In Vitro Evaluation of Adhesion of Candida Albicans on CAD/CAM PMMA-Based Polymers

Overview
Journal J Prosthodont
Specialty Dentistry
Date 2018 Jul 3
PMID 29962017
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare the amount of adherent Candida albicans to different CAD/CAM poly(methyl methacrylate) (PMMA)-based polymers and conventional heat-polymerized PMMA after long-term thermal cycling.

Materials And Methods: The specimens were subjected to 10,000 thermal cycles (5-55°C) and divided into two groups, uncoated and pellicle-coated. Surface roughness and contact angles of the specimens were measured. The surface morphology was observed with scanning electron microscopy (SEM). An adhesion test was performed by incubating the disk specimens in C. albicans suspensions at 37°C for 2 hours, and the adherent cells were counted under an optical microscope. The data were analyzed statistically using a variance analysis and Tukey HSD post hoc comparison test. The correlation between measurements was tested using a Pearson correlation analysis (α = 0.05).

Results: CAD/CAM polymers generally showed statistically significant lowest Ra and contact angle values, whereas conventional PMMA showed the highest Ra and contact angle values in the uncoated group (p < 0.05). Pellicle coating essentially increased contact angle of all materials and reduced the differences in a number of Candida cells on the materials (p < 0.05). Candida adhesion was statistically significantly greatest on conventional PMMA when compared to CAD/CAM polymers. A strong positive correlation was found between the surface roughness of the specimens (p < 0.05) and the amount of adhered cells, whereas no correlation was found between hydrophobicity of the specimens and the amount of adhered cells (p > 0.05).

Conclusions: CAD/CAM PMMA-based polymers may be preferable to reduce Candida-associated denture stomatitis in long-term use.

Citing Articles

Evaluation of the effect of new generation denture base materials aged in artificial saliva at different pH levels on surface roughness and Candida albicans adhesion.

Arslan E, Akay C, Erdonmez D, Avukat E BMC Oral Health. 2025; 25(1):356.

PMID: 40055754 PMC: 11889897. DOI: 10.1186/s12903-025-05700-4.


Comparison of marginal fit between milled and three-dimensional printed polymethylmethacrylate prostheses for single crowns, anterior bridges, and pier abutment bridges: An in vitro study.

Merchant A, Pandurangan K, Shenoy A, Nallaswamy D, Singh P J Indian Prosthodont Soc. 2025; 25(1):67-73.

PMID: 39750011 PMC: 11853941. DOI: 10.4103/jips.jips_40_24.


Effect of mechanical and chemical surface treatments on the repairing of milled and 3D-printed denture bases.

Htat H, Prawatvatchara W, Techapiroontong S, Lee J, Limpuangthip N Sci Rep. 2024; 14(1):23413.

PMID: 39379682 PMC: 11461669. DOI: 10.1038/s41598-024-75513-y.


Biofilm Formation on Denture Base Material Reinforced With a Novel Organic Material.

S M, John J, K P, Prasad K, Fahad Ismail T, Sivakumar S Cureus. 2024; 16(7):e65232.

PMID: 39184655 PMC: 11341953. DOI: 10.7759/cureus.65232.


Comparative Evaluation of Microbial Adhesion on Provisional Crowns Fabricated With Milled Polymethyl Methacrylate (PMMA) and Conventional Acrylic Resin: A Prospective Clinical Trial.

Singh P, Shenoy A, Nallaswamy D, Maiti S Cureus. 2024; 16(7):e64469.

PMID: 39135823 PMC: 11318720. DOI: 10.7759/cureus.64469.