» Articles » PMID: 37935910

Influence of Polymer Stiffness and Geometric Design on Fluid Mechanics in Tissue-Engineered Pulmonary Valve Scaffolds

Overview
Journal Ann Biomed Eng
Date 2023 Nov 7
PMID 37935910
Authors
Affiliations
Soon will be listed here.
Abstract

There is still much unknown about the fluid mechanical response to cardiac valve scaffolds, even as their implementation in the clinic is on the horizon. Specifically, while degradable polymer valve scaffolds are currently being tested in the pulmonary valve position, their material and mechanical properties have not been fully elucidated. Optimizing these properties are important determinants not only of acute function, but long-term remodeling prospects. This study aimed to characterize fluid profiles downstream of electrospun valve scaffolds under dynamic pulmonary conditions. Valve scaffold design was changed by either blending poly(carbonate urethane) urea (PCUU) with poly(ε-caprolactone) (PCL) to modulate material stiffness or by changing the geometric design of the valve scaffolds. Specifically, two designs were utilized: one modeled after a clinically used bioprosthetic valve design (termed Mk1 design), and another using a geometrically "optimized" design (termed Mk2) based on anatomical data. Particle image velocimetry results showed that material stiffness only had a mild impact on fluid mechanics, measured by velocity magnitude, vorticity, viscous shear stress, Reynolds shear stress, and turbulent kinetic energy. However, comparing the two geometric designs yielded a much greater impact, with the Mk2 valve groups containing the highest PCUU/PCL ratio demonstrating the overall best performance. This report highlights the easily manipulable design features of polymeric valve scaffolds and demonstrates their relative significance for valve function.

References
1.
Kluin J, Talacua H, Smits A, Emmert M, Brugmans M, Fioretta E . In situ heart valve tissue engineering using a bioresorbable elastomeric implant - From material design to 12 months follow-up in sheep. Biomaterials. 2017; 125:101-117. DOI: 10.1016/j.biomaterials.2017.02.007. View

2.
Bennink G, Torii S, Brugmans M, Cox M, Svanidze O, Ladich E . A novel restorative pulmonary valved conduit in a chronic sheep model: Mid-term hemodynamic function and histologic assessment. J Thorac Cardiovasc Surg. 2018; 155(6):2591-2601.e3. DOI: 10.1016/j.jtcvs.2017.12.046. View

3.
Uiterwijk M, Smits A, van Geemen D, van Klarenbosch B, Dekker S, Cramer M . In Situ Remodeling Overrules Bioinspired Scaffold Architecture of Supramolecular Elastomeric Tissue-Engineered Heart Valves. JACC Basic Transl Sci. 2021; 5(12):1187-1206. PMC: 7775962. DOI: 10.1016/j.jacbts.2020.09.011. View

4.
De Kort B, Marzi J, Brauchle E, Lichauco A, Bauer H, Serrero A . Inflammatory and regenerative processes in bioresorbable synthetic pulmonary valves up to two years in sheep-Spatiotemporal insights augmented by Raman microspectroscopy. Acta Biomater. 2021; 135:243-259. DOI: 10.1016/j.actbio.2021.09.005. View

5.
Arjunon S, Rathan S, Jo H, Yoganathan A . Aortic valve: mechanical environment and mechanobiology. Ann Biomed Eng. 2013; 41(7):1331-46. PMC: 5460154. DOI: 10.1007/s10439-013-0785-7. View