» Articles » PMID: 37892904

The Development and Biomechanical Analysis of an Allograft Interference Screw for Anterior Cruciate Ligament Reconstruction

Overview
Date 2023 Oct 28
PMID 37892904
Authors
Affiliations
Soon will be listed here.
Abstract

Graft fixation during cruciate ligament reconstruction using interference screws is a common and frequently used surgical technique. These interference screws are usually made of metal or bioabsorbable materials. This paper describes the development of an allograft interference screw from cortical human bone. During the design of the screw, particular attention was paid to the choice of the screw drive and the screw shape, as well as the thread shape. Based on these parameters, a prototype was designed and manufactured. Subsequently, the first biomechanical tests using a bovine model were performed. The test procedure comprised a torsion test to determine the ultimate failure torque of the screw and the insertion torque during graft fixation, as well as a pull-out test to asses the ultimate failure load of the graft fixation. The results of the biomechanical analysis showed that the mean value of the ultimate failure torque was 2633 Nmm, whereas the mean occurring insertion torque during graft fixation was only 1125 Nmm. The mean ultimate failure load of the graft fixation was approximately 235 N. The results of this work show a good overall performance of the allograft screw compared to conventional screws, and should serve as a starting point for further detailed investigations and studies.

References
1.
Gokeler A, Dingenen B, Hewett T . Rehabilitation and Return to Sport Testing After Anterior Cruciate Ligament Reconstruction: Where Are We in 2022?. Arthrosc Sports Med Rehabil. 2022; 4(1):e77-e82. PMC: 8811523. DOI: 10.1016/j.asmr.2021.10.025. View

2.
Schumacher T, Tushtev K, Wagner U, Becker C, Holthaus M, Hein S . A novel, hydroxyapatite-based screw-like device for anterior cruciate ligament (ACL) reconstructions. Knee. 2017; 24(5):933-939. DOI: 10.1016/j.knee.2017.07.005. View

3.
Herrera A, Martinez F, Iglesias D, Cegonino J, Ibarz E, Gracia L . Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study. BMC Musculoskelet Disord. 2010; 11:139. PMC: 2908564. DOI: 10.1186/1471-2474-11-139. View

4.
Zainal Abidin N, Ramlee M, Ab Rashid A, Ng B, Gan H, Rafiq Abdul Kadir M . Biomechanical effects of cross-pin's diameter in reconstruction of anterior cruciate ligament - A specific case study via finite element analysis. Injury. 2022; 53(7):2424-2436. DOI: 10.1016/j.injury.2022.05.021. View

5.
Lansdown D, Xiao W, Zhang A, Allen C, Feeley B, Li X . Quantitative imaging of anterior cruciate ligament (ACL) graft demonstrates longitudinal compositional changes and relationships with clinical outcomes at 2 years after ACL reconstruction. J Orthop Res. 2019; 38(6):1289-1295. PMC: 7433779. DOI: 10.1002/jor.24572. View