Total hip arthroplasty (THA) has in recent years trended toward a younger, more physically demanding patient population. Mid- to long-term studies of all ages of THA patients using highly cross-linked polyethylene (HXLPE) have been favorable, but concerns about its long-term failure and wear-related complications remain for young THA patients. In this narrative review, a search of the PubMed/MEDLINE and Cochrane databases was performed, and we identified six studies with a minimum 15-year follow-up of HXLPE with various femoral head materials. Wear-related revisions were exceedingly low for patients under the age of 55, with variable reports of non-clinically significant osteolysis. Higher activity levels, a larger femoral head size, and femoral head material were not associated with greater long-term wear rates. Young THA with metal or ceramic on HXLPE is exceedingly durable with favorable outcomes at follow-ups of over 15 years.

Citing Articles

Bilateral same-day transtrochanteric rotational osteotomy using computed tomography-based navigation: a case report.

Watanabe M, Kagaya S, Kuzushima D, Kachi I, Ishikawa T, Kanzaki K BMC Musculoskelet Disord. 2025; 26(1):235.

PMID: 40069642 PMC: 11895342. DOI: 10.1186/s12891-025-08463-9.


Foreign Body Entrapment on the Bearing Surface in Total Hip Arthroplasty: A Report of Three Cases.

Ishikura H, Kato K, Madachi A, Tanaka T, Nishiwaki T Cureus. 2025; 16(12):e76249.

PMID: 39845227 PMC: 11752405. DOI: 10.7759/cureus.76249.


Etiology, Outcomes, and Complications of Total Hip Arthroplasty in Younger Patients: A Nationwide Big Data Analysis.

Maman D, Fournier L, Steinfeld Y, Berkovich Y J Clin Med. 2024; 13(15).

PMID: 39124801 PMC: 11313375. DOI: 10.3390/jcm13154535.

References
1.
Choudhury D, Vrbka M, Mamat A, Stavness I, Roy C, Mootanah R . The impact of surface and geometry on coefficient of friction of artificial hip joints. J Mech Behav Biomed Mater. 2017; 72:192-199. DOI: 10.1016/j.jmbbm.2017.05.011. View

2.
Garcia-Rey E, Garcia-Cimbrelo E, Cruz-Pardos A . New polyethylenes in total hip replacement: A ten- to 12-year follow-up study. Bone Joint J. 2013; 95-B(3):326-32. DOI: 10.1302/0301-620X.95B3.29456. View

3.
Lang J, Whiddon D, Smith E, Salyapongse A . Use of ceramics in total hip replacement. J Surg Orthop Adv. 2008; 17(1):51-7. View

4.
Hennessy D, Callaghan J, Liu S . Second-generation extensively porous-coated THA stems at minimum 10-year followup. Clin Orthop Relat Res. 2009; 467(9):2290-6. PMC: 2866944. DOI: 10.1007/s11999-009-0831-9. View

5.
Waewsawangwong W, Goodman S . Unexpected failure of highly cross-linked polyethylene acetabular liner. J Arthroplasty. 2011; 27(2):323.e1-4. DOI: 10.1016/j.arth.2011.04.010. View