» Articles » PMID: 37752956

An Automatic Immuno-microfluidic System Integrating Electrospun Polystyrene Microfibrous Reactors for Rapid Detection of Salivary Cortisol

Overview
Journal iScience
Publisher Cell Press
Date 2023 Sep 27
PMID 37752956
Authors
Affiliations
Soon will be listed here.
Abstract

Conventional competitive enzyme-linked immunosorbent assay (ELISA) to measure the cortisol level in body fluid consumes a large amount of time, owing to complicated operations involved and requirement for precise control of reagent addition. We developed an automatic microfluidic system to detect salivary cortisol rapidly, and an electrospun polystyrene (PS) microfiber-based reactor providing considerable binding sites for antibody immobilization, thus resolving the time limitations of competitive ELISA. Cortisol sample, horseradish peroxidase (HRP)-conjugated cortisol, and 3,3',5,5'-tetramethylbenzidine (TMB) substrate were delivered to the PS reactor from containers in sequence by pumps automatically. The color variation due to oxidized TMB complex reflects the cortisol concentration level measured using an RGB phototransistor. In addition, the entire procedure from sample introduction to obtaining the photocurrent took only 15 min. This system can be implemented to quantify cortisol from 0.37 ng/mL to 30 ng/mL, and the limit of detection was estimated at 0.37 ng/mL.

Citing Articles

A Highly Sensitive Dual-Drive Microfluidic Device for Multiplexed Detection of Respiratory Virus Antigens.

Yang X, Li Y, Lee J, Sun Y, Tan X, Liu Y Micromachines (Basel). 2024; 15(6).

PMID: 38930655 PMC: 11206039. DOI: 10.3390/mi15060685.

References
1.
LAUDAT M, Cerdas S, Fournier C, Guiban D, Guilhaume B, LUTON J . Salivary cortisol measurement: a practical approach to assess pituitary-adrenal function. J Clin Endocrinol Metab. 1988; 66(2):343-8. DOI: 10.1210/jcem-66-2-343. View

2.
Sakihara S, Kageyama K, Oki Y, Doi M, Iwasaki Y, Takayasu S . Evaluation of plasma, salivary, and urinary cortisol levels for diagnosis of Cushing's syndrome. Endocr J. 2010; 57(4):331-7. DOI: 10.1507/endocrj.k09e-340. View

3.
Arya S, Chornokur G, Venugopal M, Bhansali S . Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol. Biosens Bioelectron. 2010; 25(10):2296-301. PMC: 2869627. DOI: 10.1016/j.bios.2010.03.016. View

4.
Tlili C, Myung N, Shetty V, Mulchandani A . Label-free, chemiresistor immunosensor for stress biomarker cortisol in saliva. Biosens Bioelectron. 2011; 26(11):4382-6. DOI: 10.1016/j.bios.2011.04.045. View

5.
Yousif E, Haddad R . Photodegradation and photostabilization of polymers, especially polystyrene: review. Springerplus. 2015; 2:398. PMC: 4320144. DOI: 10.1186/2193-1801-2-398. View