Salivary Cortisol Measurement: a Practical Approach to Assess Pituitary-adrenal Function

Overview
Specialty Endocrinology
Date 1988 Feb 1
PMID 2828410
Citations 49
Authors
Affiliations
Soon will be listed here.
Abstract

The salivary cortisol concentration is an excellent indicator of the plasma free cortisol concentration. To establish its normal and pathological ranges, salivary cortisol concentrations were measured in 101 normal adults, 18 patients with Cushing's syndrome, and 21 patients with adrenal insufficiency. The normal subjects had a mean (+/- SEM) salivary cortisol concentration of 15.5 +/- 0.8 nmol/L (range, 10.2-27.3) at 0800 h and 3.9 +/- 0.2 nmol/L (range, 2.2-4.1) at 2000 h (n = 20). The mean value 60 min after ACTH administration in 58 normal subjects was 52.2 +/- 2.2 nmol/L (range, 23.5-99.4), and it was 1.4 +/- 1.1 nmol/L (range, 1.6-3) at 0800 h in 23 normal subjects given 1 mg dexamethasone 8 h earlier. In patients with primary or secondary adrenal insufficiency (n = 21) the mean salivary cortisol level was 7.5 +/- 0.4 nmol/L (range, 1.9-21.8) 60 min after ACTH. In patients with Cushing's syndrome (n = 7), the mean value after the 1-mg dexamethasone suppression test was 16.1 +/- 7.8 nmol/L (range, 5.8-66.8). No overlap was found between the values in the normal subjects and those in the patients during the dynamic tests. Discrepancies between salivary and total plasma cortisol were found in 8 patients with adrenal insufficiency, which may be explained by the effects of drugs such as thyroid hormones, Op'-dichlorodiphenyldichloroethane, and psychotropic agents. We conclude that salivary cortisol measurements are an excellent index of plasma free cortisol concentrations. They circumvent the physiological, pathological, and pharmacological changes due to corticosteroid-binding globulin alterations and offer a practical approach to assess pituitary-adrenal function.

Citing Articles

Salivary Cortisol Concentration Is an Objective Measure of the Physiological Response to Loud Music.

Tomljenovic R, Kosec A, Kalogjera L, Celap I, Marijancevic D, Vagic D Audiol Res. 2024; 14(6):1093-1104.

PMID: 39727613 PMC: 11673928. DOI: 10.3390/audiolres14060090.


Determination of cortisol cut-off limits and steroid dynamics in the ACTH stimulation test: a comparative analysis using Roche Elecsys Cortisol II immunoassay and LC-MS/MS.

Okutan S, Jorgensen N, Pedersen L, Borresen S, Hilsted L, Hansen L Endocrine. 2024; 85(1):321-330.

PMID: 38460071 PMC: 11246257. DOI: 10.1007/s12020-024-03752-0.


Rational Approach to Optimizing Conformation-Switching Aptamers for Biosensing Applications.

Wolfe M, Cramer A, Webb S, Goorskey E, Chushak Y, Mirau P ACS Sens. 2024; 9(2):717-725.

PMID: 38270529 PMC: 10897929. DOI: 10.1021/acssensors.3c02004.


Salivary Cortisol and Cortisone Can Circumvent Confounding Effects of Oral Contraceptives in the Short Synacthen Test.

Backlund N, Lundstedt S, Tornevi A, Wihlback A, Olsson T, Dahlqvist P J Clin Endocrinol Metab. 2024; 109(7):1899-1906.

PMID: 38173358 PMC: 11180507. DOI: 10.1210/clinem/dgad763.


An automatic immuno-microfluidic system integrating electrospun polystyrene microfibrous reactors for rapid detection of salivary cortisol.

Wang Y, Murakami H, Kasama T, Mitsuzawa S, Shinkawa S, Miyake R iScience. 2023; 26(10):107820.

PMID: 37752956 PMC: 10518708. DOI: 10.1016/j.isci.2023.107820.