Comparative Study of the Osseointegration of 3D-printed and Plasma-coated Titanium Implants
Overview
Authors
Affiliations
Background: Total hip arthroplasty is a common surgical treatment for elderly patients with osteoporosis, particularly in postmenopausal women. In such cases, highly porous acetabular components are a favorable option in achieving osseointegration. However, further discussion is needed if use of such acetabular components is justified under the condition of normal bone mass.
Aim: To determine the features of osseointegration of two different types of titanium implants [3-dimensional (3D)-printed and plasma-coated titanium implants] in bone tissue of a distal metaphysis in a rat femur model.
Methods: This study was performed on 20 white male laboratory rats weighing 300-350 g aged 6 mo. Rats were divided into two groups of 10 animals, which had two different types of implants were inserted into a hole defect (2 × 3 mm) in the distal metaphysis of the femur: Group I: 3D-printed titanium implant (highly porous); Group II: Plasma-coated titanium implant. After 45 and 90 d following surgery, the rats were sacrificed, and their implanted femurs were extracted for histological examination. The relative perimeter (%) of bone trabeculae [bone-implant contact (BIC%)] and bone marrow surrounding the titanium implants was measured.
Results: Trabecular bone tissue was formed on the 45 day after implantation around the implants regardless of their type. 45 d after surgery, group I (3D-printed titanium implant) and group II (plasma-coated titanium implant) did not differ in BIC% (83.51 ± 8.5 84.12 ± 1 .73; = 0.838). After 90 d, the BIC% was higher in group I (87.04 ± 6.99 81.24 ± 7.62; = 0.049), compared to group II. The relative perimeter of the bone marrow after 45 d did not differ between groups and was 16.49% ± 8.58% for group I, and 15.88% ± 1.73% for group II. Futhermore, after 90 d, in group I the relative perimeter of bone marrow was 1.4 times smaller (12.96 ± 6.99 18.76 ± 7.62; = 0.049) compared to the relative perimeter of bone marrow in group II.
Conclusion: The use of a highly porous titanium implant, manufactured with 3D printing, for acetabular components provides increased osseointegration compared to a plasma-coated titanium implant.
Liang W, Zhou C, Liu X, Xie Q, Xia L, Li Q Int J Nanomedicine. 2025; 20:2205-2223.
PMID: 39990287 PMC: 11847438. DOI: 10.2147/IJN.S501963.
Liu B, Wang L, Li X, Chen Z, Hou G, Zhou F J Orthop Surg Res. 2024; 19(1):418.
PMID: 39033286 PMC: 11264997. DOI: 10.1186/s13018-024-04926-2.