» Articles » PMID: 37373418

Bioactive and Elastic Emulsion Electrospun DegraPol Tubes Delivering IGF-1 for Tendon Rupture Repair

Abstract

Tendon injuries can result in two major drawbacks. Adhesions to the surrounding tissue may limit the range of motion, while fibrovascular scar formation can lead to poor biomechanical outcomes. Prosthetic devices may help to mitigate those problems. Emulsion electrospinning was used to develop a novel three-layer tube based on the polymer DegraPol (DP), with incorporated insulin-like growth factor-1 (IGF-1) in the middle layer. Scanning electron microscopy was utilized to assess the fiber diameter in IGF-1 containing pure DP meshes. Further characterization was performed with Fourier Transformed Infrared Spectroscopy, Differential Scanning Calorimetry, and water contact angle, as well as through the assessment of mechanical properties and release kinetics from ELISA, and the bioactivity of IGF-1 by qPCR of , and in rabbit Achilles tenocytes. The IGF-1-containing tubes exhibited a sustained release of the growth factor up to 4 days and showed bioactivity by significantly upregulated and gene expression. Moreover, they proved to be mechanically superior to pure DP tubes (significantly higher fracture strain, failure stress, and elastic modulus). The novel three-layer tubes intended to be applied over conventionally sutured tendons after a rupture may help accelerate the healing process. The release of IGF-1 stimulates proliferation and matrix synthesis of cells at the repair site. In addition, adhesion formation to surrounding tissue can be reduced due to the physical barrier.

Citing Articles

Fabrication and Characterization of Electrospun DegraPol Tubes Releasing TIMP-1 Protein to Modulate Tendon Healing.

Rieber J, Niederhauser R, Giovanoli P, Buschmann J Materials (Basel). 2025; 18(3).

PMID: 39942332 PMC: 11820012. DOI: 10.3390/ma18030665.


Mechanical, water contact angle and fiber thickness data for Insulin-like growth gactor-1 (IGF-1) incorporated in electrospun random DegraPol fibers and IGF-1 impact on tenocyte aspect ratio and gene expression data.

Rieber J, Meier-Burgisser G, Miescher I, Weber F, Wolint P, Yang Y Data Brief. 2024; 57:111139.

PMID: 39687367 PMC: 11647151. DOI: 10.1016/j.dib.2024.111139.


Fibrin Scaffolds Perfused with Transforming Growth Factor-β1 as an In Vitro Model to Study Healthy and Tendinopathic Human Tendon Stem/Progenitor Cells.

Ciardulli M, Lovecchio J, Parolini O, Giordano E, Maffulli N, Della Porta G Int J Mol Sci. 2024; 25(17).

PMID: 39273510 PMC: 11395617. DOI: 10.3390/ijms25179563.


Optimizing tendon repair and regeneration: how does the environment shape outcomes following rupture of a tendon such as the Achilles tendon?.

Hart D, Ahmed A, Chen J, Ackermann P Front Bioeng Biotechnol. 2024; 12:1357871.

PMID: 38433820 PMC: 10905747. DOI: 10.3389/fbioe.2024.1357871.


Electrosprayed Core (Cellulose Acetate)-Shell (Polyvinylpyrrolidone) Nanoparticles for Smart Acetaminophen Delivery.

Xu L, He H, Du Y, Zhang S, Yu D, Liu P Pharmaceutics. 2023; 15(9).

PMID: 37765283 PMC: 10537010. DOI: 10.3390/pharmaceutics15092314.

References
1.
Yoo J, Won Y . Phenomenology of the Initial Burst Release of Drugs from PLGA Microparticles. ACS Biomater Sci Eng. 2021; 6(11):6053-6062. DOI: 10.1021/acsbiomaterials.0c01228. View

2.
Yang G, Rothrauff B, Tuan R . Tendon and ligament regeneration and repair: clinical relevance and developmental paradigm. Birth Defects Res C Embryo Today. 2013; 99(3):203-222. PMC: 4041869. DOI: 10.1002/bdrc.21041. View

3.
Evrova O, Kellenberger D, Scalera C, Calcagni M, Giovanoli P, Vogel V . Impact of UV sterilization and short term storage on the in vitro release kinetics and bioactivity of biomolecules from electrospun scaffolds. Sci Rep. 2019; 9(1):15117. PMC: 6805903. DOI: 10.1038/s41598-019-51513-1. View

4.
Chartier C, ElHawary H, Baradaran A, Vorstenbosch J, Xu L, Efanov J . Tendon: Principles of Healing and Repair. Semin Plast Surg. 2021; 35(3):211-215. PMC: 8432990. DOI: 10.1055/s-0041-1731632. View

5.
Meier Burgisser G, Evrova O, Heuberger D, Wolint P, Rieber J, Miescher I . Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression. Sci Rep. 2021; 11(1):23293. PMC: 8639666. DOI: 10.1038/s41598-021-02780-4. View