» Articles » PMID: 3731423

Noninvasive Evaluation of Left Ventricular Performance Based on Peak Aortic Blood Acceleration Measured with a Continuous-wave Doppler Velocity Meter

Overview
Journal Circulation
Date 1986 Aug 1
PMID 3731423
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Peak aortic blood acceleration is recognized to be a sensitive index of global left ventricular performance. In the present study peak acceleration was assessed noninvasively in patients with a continuous-wave Doppler velocity meter. Peak aortic blood velocity and peak blood acceleration were measured by placing the ultrasonic transducer at the suprasternal notch. Measurements were obtained in 36 patients undergoing diagnostic cardiac catheterization. Peak velocity and acceleration were measured at rest just before left ventriculography. In patients with ejection fractions greater than 60%, peak acceleration was 19 +/- 5 m/sec/sec. In patients with ejection fractions of 41% to 60%, peak acceleration was lower, at 12 +/- 2 m/sec/sec (p less than .001). In patients with ejection fractions of 40% or less, peak acceleration (8 +/- 2 m/sec/sec) was markedly lower than in patients with ejection fractions greater than 60% (p less than .001). Peak acceleration showed a good linear correlation with ejection fraction (r = .90), and a better power fit (r = .93). These results indicate that peak acceleration, measured noninvasively with a continuous-wave Doppler velocity meter, is a useful indicator of global left ventricular performance.

Citing Articles

Rapid Transient Transcriptional Adaptation to Hypergravity in Jurkat T Cells Revealed by Comparative Analysis of Microarray and RNA-Seq Data.

Vahlensieck C, Thiel C, Adelmann J, Lauber B, Polzer J, Ullrich O Int J Mol Sci. 2021; 22(16).

PMID: 34445156 PMC: 8395121. DOI: 10.3390/ijms22168451.


Dynamic Arterial Elastance During Experimental Endotoxic Septic Shock: A Potential Marker of Cardiovascular Efficiency.

Monge Garcia M, Guijo Gonzalez P, Saludes Orduna P, Gracia Romero M, Gil Cano A, Messina A Front Physiol. 2020; 11:562824.

PMID: 33123025 PMC: 7567029. DOI: 10.3389/fphys.2020.562824.


A case of hypertrophic obstructive cardiomyopathy with aortic stenosis.

Ishimura M, Takayama M, Saji M, Takamisawa I, Umemura J, Sumiyoshi T J Cardiol Cases. 2018; 9(4):129-133.

PMID: 30546782 PMC: 6281696. DOI: 10.1016/j.jccase.2013.12.003.


Assessing mental stress from the photoplethysmogram: a numerical study.

Charlton P, Celka P, Farukh B, Chowienczyk P, Alastruey J Physiol Meas. 2018; 39(5):054001.

PMID: 29658894 PMC: 5964362. DOI: 10.1088/1361-6579/aabe6a.


Fluid-structure interaction of an aortic heart valve prosthesis driven by an animated anatomic left ventricle.

Le T, Sotiropoulos F J Comput Phys. 2013; 244:41-62.

PMID: 23729841 PMC: 3667163. DOI: 10.1016/j.jcp.2012.08.036.