» Articles » PMID: 37308297

Concurrent Measurement of Perfusion Parameters Related to Small Blood Vessels and Cerebrospinal Fluid Circulation in the Human Brain Using Dynamic Dual-spin-echo Perfusion MRI

Overview
Journal NMR Biomed
Publisher Wiley
Date 2023 Jun 12
PMID 37308297
Authors
Affiliations
Soon will be listed here.
Abstract

Accumulating evidence from recent studies has indicated the importance of studying the interaction between the microvascular and lymphatic systems in the brain. To date, most imaging methods can only measure blood or lymphatic vessels separately, such as dynamic susceptibility contrast (DSC) MRI for blood vessels and DSC MRI-in-the-cerebrospinal fluid (CSF) (cDSC MRI) for lymphatic vessels. An approach that can measure both blood and lymphatic vessels in a single scan offers advantages such as a halved scan time and contrast dosage. This study attempts to develop one such approach by optimizing a dual-echo turbo-spin-echo sequence, termed "dynamic dual-spin-echo perfusion (DDSEP) MRI". Bloch simulations were performed to optimize the dual-echo sequence for the measurement of gadolinium (Gd)-induced blood and CSF signal changes using a short and a long echo time, respectively. The proposed method furnishes a T1-dominant contrast in CSF and a T2-dominant contrast in blood. MRI experiments were performed in healthy subjects to evaluate the dual-echo approach by comparing it with existing separate methods. Based on simulations, the short and long echo time were chosen around the time when blood signals show maximum difference between post- and pre-Gd scans, and the time when blood signals are completely suppressed, respectively. The proposed method showed consistent results in human brains as previous studies using separate methods. Signal changes from small blood vessels occurred faster than from lymphatic vessels after intravenous Gd injection. In conclusion, Gd-induced signal changes in blood and CSF can be detected simultaneously in healthy subjects with the proposed sequence. The temporal difference in Gd-induced signal changes from small blood and lymphatic vessels after intravenous Gd injection was confirmed using the proposed approach in the same human subjects. Results from this proof-of-concept study will be used to further optimize DDSEP MRI in subsequent studies.

Citing Articles

Diffusion magnetic resonance imaging of cerebrospinal fluid dynamics: Current techniques and future advancements.

Wright A, Wu Y, Feng L, Wen Q NMR Biomed. 2024; 37(9):e5162.

PMID: 38715420 PMC: 11303114. DOI: 10.1002/nbm.5162.


Exploring neurodegenerative disorders using advanced magnetic resonance imaging of the glymphatic system.

Prasuhn J, Xu J, Hua J, van Zijl P, Knutsson L Front Psychiatry. 2024; 15:1368489.

PMID: 38651012 PMC: 11033437. DOI: 10.3389/fpsyt.2024.1368489.


Neurofluids and the glymphatic system: anatomy, physiology, and imaging.

Wang D, Hua J, Cao D, Ho M Br J Radiol. 2023; 96(1151):20230016.

PMID: 37191063 PMC: 10607419. DOI: 10.1259/bjr.20230016.

References
1.
Absinta M, Vuolo L, Rao A, Nair G, Sati P, Cortese I . Gadolinium-based MRI characterization of leptomeningeal inflammation in multiple sclerosis. Neurology. 2015; 85(1):18-28. PMC: 4501940. DOI: 10.1212/WNL.0000000000001587. View

2.
Lee H, Mortensen K, Sanggaard S, Koch P, Brunner H, Quistorff B . Quantitative Gd-DOTA uptake from cerebrospinal fluid into rat brain using 3D VFA-SPGR at 9.4T. Magn Reson Med. 2017; 79(3):1568-1578. PMC: 5736474. DOI: 10.1002/mrm.26779. View

3.
Stokes A, Skinner J, Quarles C . Assessment of a combined spin- and gradient-echo (SAGE) DSC-MRI method for preclinical neuroimaging. Magn Reson Imaging. 2014; 32(10):1181-90. PMC: 4254163. DOI: 10.1016/j.mri.2014.08.027. View

4.
Fujima N, Kudo K, Tsukahara A, Yoshida D, Sakashita T, Homma A . Measurement of tumor blood flow in head and neck squamous cell carcinoma by pseudo-continuous arterial spin labeling: comparison with dynamic contrast-enhanced MRI. J Magn Reson Imaging. 2015; 41(4):983-91. DOI: 10.1002/jmri.24885. View

5.
Absinta M, Ha S, Nair G, Sati P, Luciano N, Palisoc M . Human and nonhuman primate meninges harbor lymphatic vessels that can be visualized noninvasively by MRI. Elife. 2017; 6. PMC: 5626482. DOI: 10.7554/eLife.29738. View