» Articles » PMID: 37240600

Radiographic Analysis in Extra-Articular and Intra-Articular Distal Radius Fractures Treated with Variable-Angle Volar Locking Plate Fixation

Overview
Journal J Clin Med
Specialty General Medicine
Date 2023 May 27
PMID 37240600
Authors
Affiliations
Soon will be listed here.
Abstract

(1) Background: Different distal radial fracture types have different prognosis after fixation. Our study aim is to evaluate the differences in radiographic parameters by using variable-angle volar locking plate (VAVLP) fixation according to extra-articular and intra-articular distal radial fracture. (2) Methods: There are two groups: extra-articular group (21) and intra-articular group (25). Forearm radiographs immediately after surgery and at 3 months after operation were reviewed for analyzing radial height (RH), ulnar variance (UV), radial inclination (RI), volar tilt (VT), tear drop angle (TDA), distal dorsal cortical distance (DDD), and Soong classification (SC). (3) Results: There were no significant differences in the above parameters between two groups at either immediately post-operative or at 3-month follow-up, except for TDA ( = 0.048). Most patients in both groups were at low risk of flexor tendon rupture, except for two cases. We observed a positive correlation between post-operative DDD and 3-month change in the intra-articular group, but not the extra-articular group. (4) Conclusions: Our study demonstrates that VAVLP fixation is effective in maintaining the stability of most radiographic parameters and reduces the risk of tendon rupture in both extra-articular and intra-articular distal radial fractures. Post-operative DDD can be used to predict the degree of subsequent displacement in patients with intra-articular fractures fixed with VAVLP.

Citing Articles

Predictive factors of distal radioulnar joint instability after surgical treatment of distal radius fractures.

Li C, Kong L, Shi X, Zhang Z, Lu J, Zhang B Medicine (Baltimore). 2023; 102(48):e36505.

PMID: 38050192 PMC: 10695496. DOI: 10.1097/MD.0000000000036505.

References
1.
Kreder H, Hanel D, McKee M, Jupiter J, McGillivary G, Swiontkowski M . X-ray film measurements for healed distal radius fractures. J Hand Surg Am. 1996; 21(1):31-9. DOI: 10.1016/S0363-5023(96)80151-1. View

2.
Khatri K, Sharma V, Farooque K, Tiwari V . Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes. Arch Trauma Res. 2016; 5(2):e25174. PMC: 5035514. DOI: 10.5812/atr.25174. View

3.
Vosbikian M, Ketonis C, Huang R, Ilyas A . Optimal Positioning for Volar Plate Fixation of a Distal Radius Fracture: Determining the Distal Dorsal Cortical Distance. Orthop Clin North Am. 2015; 47(1):235-44. DOI: 10.1016/j.ocl.2015.08.020. View

4.
Mehrzad R, Kim D . Complication Rate Comparing Variable Angle Distal Locking Plate to Fixed Angle Plate Fixation of Distal Radius Fractures. Ann Plast Surg. 2016; 77(6):623-625. DOI: 10.1097/SAP.0000000000000850. View

5.
Snoddy M, An T, Hooe B, Kay H, Lee D, Pappas N . Incidence and reasons for hardware removal following operative fixation of distal radius fractures. J Hand Surg Am. 2015; 40(3):505-7. DOI: 10.1016/j.jhsa.2014.11.022. View