» Articles » PMID: 34722085

Early Results of a Variable-Angle Volar Locking Plate for Distal Radius Fractures: A Bi-centre Study

Overview
Journal Cureus
Date 2021 Nov 1
PMID 34722085
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose This study examines the clinical, functional and radiological outcomes of distal radius fracture fixation with the Aptus® (Medartis, Pennsylvania) locking plate in order to determine its efficacy and identify notable findings related to treatment variations. Methods This is a retrospective bi-centre study collecting patient details from a district general hospital and a regional hand unit. We assessed 61 consecutive patients with distal radius fractures (Arbeitsgemeinschaft für Osteosynthesefragen (AO) grade A=19, B=9, C=33) fixed using an Aptus® plate with a minimum of six months follow-up. Outcome measures included the DASH (Disabilities of the Arm, Shoulder and Hand) score, wrist range of movement and grip strength, and complications. Radiographs were reviewed to assess restoration of anatomy and union. Results All but two fractures united within six weeks. The mean ranges of movement were only mildly restricted compared to the normal wrist (flexion/extension = 102°; radial/ulna deviation = 53°; pronation/supination = 169°). Mean postoperative grip strength was 23.8 kg, which was comparable to the contralateral side at 31.5 kg. The mean DASH score was 18.2. Seven patients had screws misplaced outside the distal radius although three of these remained asymptomatic. Conclusion Variable-angle locking systems benefit from the flexibility of implant positioning and may allow enhanced inter-fragmentary reduction for accurate fixation of intra-articular fractures.

Citing Articles

Complications after volar plate synthesis for distal radius fractures.

Pacchiarini L, Oldrini L, Feltri P, Lucchina S, Filardo G, Candrian C EFORT Open Rev. 2024; 9(6):567-580.

PMID: 38828969 PMC: 11195338. DOI: 10.1530/EOR-23-0188.


Radiographic Analysis in Extra-Articular and Intra-Articular Distal Radius Fractures Treated with Variable-Angle Volar Locking Plate Fixation.

Fang P, Lo T, Cheng C, Wu C, Chen A J Clin Med. 2023; 12(10).

PMID: 37240600 PMC: 10219571. DOI: 10.3390/jcm12103494.


Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?.

S J K, Ethiraj P Cureus. 2022; 14(11):e31427.

PMID: 36523730 PMC: 9745101. DOI: 10.7759/cureus.31427.


Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes.

Khatri K, Sharma V, Farooque K, Tiwari V Arch Trauma Res. 2016; 5(2):e25174.

PMID: 27679785 PMC: 5035514. DOI: 10.5812/atr.25174.

References
1.
GARTLAND Jr J, WERLEY C . Evaluation of healed Colles' fractures. J Bone Joint Surg Am. 1951; 33-A(4):895-907. View

2.
Rozental T, Blazar P . Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006; 31(3):359-65. DOI: 10.1016/j.jhsa.2005.10.010. View

3.
Kreder H, Hanel D, McKee M, Jupiter J, McGillivary G, Swiontkowski M . X-ray film measurements for healed distal radius fractures. J Hand Surg Am. 1996; 21(1):31-9. DOI: 10.1016/S0363-5023(96)80151-1. View

4.
Schmelzer-Schmied N, Wieloch P, Martini A, Daecke W . Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly. Int Orthop. 2008; 33(3):773-8. PMC: 2903102. DOI: 10.1007/s00264-007-0504-9. View

5.
Jupiter J, Marent-Huber M . Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg Am. 2009; 91(1):55-65. DOI: 10.2106/JBJS.G.01498. View