» Articles » PMID: 37206127

Effect of Fixational Eye Movements in Corneal Topography Measurements with Optical Coherence Tomography

Overview
Specialty Radiology
Date 2023 May 19
PMID 37206127
Authors
Affiliations
Soon will be listed here.
Abstract

There is an increasing interest in applying optical coherence tomography (OCT) to quantify the topography of ocular structures. However, in its most usual configuration, OCT data is acquired sequentially while a beam is scanned through the region of interest, and the presence of fixational eye movements can affect the accuracy of the technique. Several scan patterns and motion correction algorithms have been proposed to minimize this effect, but there is no consensus on the ideal parameters to obtain a correct topography. We have acquired corneal OCT images with raster and radial patterns, and modeled the data acquisition in the presence of eye movements. The simulations replicate the experimental variability in shape (radius of curvature and Zernike polynomials), corneal power, astigmatism, and calculated wavefront aberrations. The variability of the Zernike modes is highly dependent on the scan pattern, with higher variability in the direction of the slow scan axis. The model can be a useful tool to design motion correction algorithms and to determine the variability with different scan patterns.

Citing Articles

Introduction to Visual and Physiological Optics feature issue of .

Tabernero J, Lundstrom L, Schwarz C, Vohnsen B Biomed Opt Express. 2023; 14(7):3853-3855.

PMID: 37497525 PMC: 10368042. DOI: 10.1364/BOE.499269.

References
1.
Marcos S, Martinez-Enriquez E, Vinas M, de Castro A, Dorronsoro C, Bang S . Simulating Outcomes of Cataract Surgery: Important Advances in Ophthalmology. Annu Rev Biomed Eng. 2021; 23:277-306. DOI: 10.1146/annurev-bioeng-082420-035827. View

2.
Leung M, Mariampillai A, Standish B, Lee K, Munce N, Vitkin I . High-power wavelength-swept laser in Littman telescope-less polygon filter and dual-amplifier configuration for multichannel optical coherence tomography. Opt Lett. 2009; 34(18):2814-6. DOI: 10.1364/OL.34.002814. View

3.
Ortiz S, Siedlecki D, Perez-Merino P, Chia N, de Castro A, Szkulmowski M . Corneal topography from spectral optical coherence tomography (sOCT). Biomed Opt Express. 2011; 2(12):3232-47. PMC: 3233243. DOI: 10.1364/BOE.2.003232. View

4.
Pavlatos E, Huang D, Li Y . Eye motion correction algorithm for OCT-based corneal topography. Biomed Opt Express. 2021; 11(12):7343-7356. PMC: 7747916. DOI: 10.1364/BOE.412209. View

5.
Chen Y, Manzanera S, Mompean J, Ruminski D, Grulkowski I, Artal P . Increased crystalline lens coverage in optical coherence tomography with oblique scanning and volume stitching. Biomed Opt Express. 2021; 12(3):1529-1542. PMC: 7984769. DOI: 10.1364/BOE.418051. View