» Articles » PMID: 37189533

Comparative Clinical Evaluation of a Novel FluA/FluB/SARS-CoV-2 Multiplex LAMP and Commercial FluA/FluB/SARS-CoV-2/RSV RT-qPCR Assays

Overview
Specialty Radiology
Date 2023 May 16
PMID 37189533
Authors
Affiliations
Soon will be listed here.
Abstract

Influenza and coronaviruses cause highly contagious respiratory diseases that cause millions of deaths worldwide. Public health measures implemented during the current coronavirus disease (COVID-19) pandemic have gradually reduced influenza circulation worldwide. As COVID-19 measures have relaxed, it is necessary to monitor and control seasonal influenza during this COVID-19 pandemic. In particular, the development of rapid and accurate diagnostic methods for influenza and COVID-19 is of paramount importance because both diseases have significant public health and economic impacts. To address this, we developed a multi-loop-mediated isothermal amplification (LAMP) kit capable of simultaneously detecting influenza A/B and SARS-CoV-2. The kit was optimized by testing various ratios of primer sets for influenza A/B (FluA/FluB) and SARS-CoV-2 and internal control (IC). The FluA/FluB/SARS-CoV-2 multiplex LAMP assay showed 100% specificity for uninfected clinical samples and sensitivities of 90.6%, 86.89%, and 98.96% for LAMP kits against influenza A, influenza B, and SARS-CoV-2 clinical samples, respectively. Finally, the attribute agreement analysis for clinical tests indicated substantial agreement between the multiplex FluA/FluB/SARS-CoV-2/IC LAMP and commercial Allplex SARS-CoV-2/FluA/FluB/RSV assays.

Citing Articles

A novel single-tube LAMP-CRISPR/Cas12b method for rapid and visual detection of zoonotic Toxoplasma gondii in the environment.

Liang Y, Xie S, Lv Y, He Y, Zheng X, Cong W Infect Dis Poverty. 2024; 13(1):94.

PMID: 39654027 PMC: 11629535. DOI: 10.1186/s40249-024-01266-5.


Enhanced Point-of-Care SARS-CoV-2 Detection: Integrating RT-LAMP with Microscanning.

Choi M, Lee E, Park S, Lim C, Jang W Biosensors (Basel). 2024; 14(7).

PMID: 39056624 PMC: 11274610. DOI: 10.3390/bios14070348.


Loop-Mediated Isothermal Amplification and Lateral Flow Immunochromatography Technology for Rapid Diagnosis of Influenza A/B.

Jang W, Lee J, Lee E, Park S, Lim C Diagnostics (Basel). 2024; 14(9).

PMID: 38732380 PMC: 11083224. DOI: 10.3390/diagnostics14090967.

References
1.
Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N . Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000; 28(12):E63. PMC: 102748. DOI: 10.1093/nar/28.12.e63. View

2.
Takayama I, Nakauchi M, Takahashi H, Oba K, Semba S, Kaida A . Development of real-time fluorescent reverse transcription loop-mediated isothermal amplification assay with quenching primer for influenza virus and respiratory syncytial virus. J Virol Methods. 2019; 267:53-58. PMC: 7113748. DOI: 10.1016/j.jviromet.2019.02.010. View

3.
Javanian M, Barary M, Ghebrehewet S, Koppolu V, Vasigala V, Ebrahimpour S . A brief review of influenza virus infection. J Med Virol. 2021; 93(8):4638-4646. DOI: 10.1002/jmv.26990. View

4.
Mboumba Bouassa R, Tonen-Wolyec S, Veyer D, Pere H, Belec L . Analytical performances of the AMPLIQUICK® Respiratory Triplex assay for simultaneous detection and differentiation of SARS-CoV-2, influenza A/B and respiratory syncytial viruses in respiratory specimens. PLoS One. 2022; 17(1):e0262258. PMC: 8730414. DOI: 10.1371/journal.pone.0262258. View

5.
Irsara C, Egger A, Prokop W, Nairz M, Loacker L, Sahanic S . Evaluation of four commercial, fully automated SARS-CoV-2 antibody tests suggests a revision of the Siemens SARS-CoV-2 IgG assay. Clin Chem Lab Med. 2021; 59(6):1143-1154. DOI: 10.1515/cclm-2020-1758. View