» Articles » PMID: 37066854

Stochastic Optimization of Three-dimensional Non-Cartesian Sampling Trajectory

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2023 Apr 17
PMID 37066854
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Optimizing three-dimensional (3D) k-space sampling trajectories is important for efficient MRI yet presents a challenging computational problem. This work proposes a generalized framework for optimizing 3D non-Cartesian sampling patterns via data-driven optimization.

Methods: We built a differentiable simulation model to enable gradient-based methods for sampling trajectory optimization. The algorithm can simultaneously optimize multiple properties of sampling patterns, including image quality, hardware constraints (maximum slew rate and gradient strength), reduced peripheral nerve stimulation (PNS), and parameter-weighted contrast. The proposed method can either optimize the gradient waveform (spline-based freeform optimization) or optimize properties of given sampling trajectories (such as the rotation angle of radial trajectories). Notably, the method can optimize sampling trajectories synergistically with either model-based or learning-based reconstruction methods. We proposed several strategies to alleviate the severe nonconvexity and huge computation demand posed by the large scale. The corresponding code is available as an open-source toolbox.

Results: We applied the optimized trajectory to multiple applications including structural and functional imaging. In the simulation studies, the image quality of a 3D kooshball trajectory was improved from 0.29 to 0.22 (NRMSE) with Stochastic optimization framework for 3D NOn-Cartesian samPling trajectorY (SNOPY) optimization. In the prospective studies, by optimizing the rotation angles of a stack-of-stars (SOS) trajectory, SNOPY reduced the NRMSE of reconstructed images from 1.19 to 0.97 compared to the best empirical method (RSOS-GR). Optimizing the gradient waveform of a rotational EPI trajectory improved participants' rating of the PNS from "strong" to "mild."

Conclusion: SNOPY provides an efficient data-driven and optimization-based method to tailor non-Cartesian sampling trajectories.

Citing Articles

Advancing MRI Reconstruction: A Systematic Review of Deep Learning and Compressed Sensing Integration.

Safari M, Eidex Z, Chang C, Qiu R, Yang X ArXiv. 2025; .

PMID: 39975448 PMC: 11838702.


Electric potential energy optimized 3D radial sampling trajectories for MRI.

Huynh C, Goolaub D, Macgowan C Sci Rep. 2024; 14(1):24084.

PMID: 39406755 PMC: 11480509. DOI: 10.1038/s41598-024-74437-x.


3D MR fingerprinting for dynamic contrast-enhanced imaging of whole mouse brain.

Zhu Y, Wang G, Gu Y, Zhao W, Lu J, Zhu J Magn Reson Med. 2024; 93(1):67-79.

PMID: 39164799 PMC: 11518651. DOI: 10.1002/mrm.30253.


AutoSamp: Autoencoding k-Space Sampling via Variational Information Maximization for 3D MRI.

Alkan C, Mardani M, Liao C, Li Z, Vasanawala S, Pauly J IEEE Trans Med Imaging. 2024; 44(1):270-283.

PMID: 39146168 PMC: 11828943. DOI: 10.1109/TMI.2024.3443292.


Artificial intelligence for neuro MRI acquisition: a review.

Yang H, Wang G, Li Z, Li H, Zheng J, Hu Y MAGMA. 2024; 37(3):383-396.

PMID: 38922525 DOI: 10.1007/s10334-024-01182-7.


References
1.
Maier O, Baete S, Fyrdahl A, Hammernik K, Harrevelt S, Kasper L . CG-SENSE revisited: Results from the first ISMRM reproducibility challenge. Magn Reson Med. 2020; 85(4):1821-1839. PMC: 8201869. DOI: 10.1002/mrm.28569. View

2.
Guo S, Noll D . Oscillating steady-state imaging (OSSI): A novel method for functional MRI. Magn Reson Med. 2020; 84(2):698-712. PMC: 7180136. DOI: 10.1002/mrm.28156. View

3.
Giliyar Radhakrishna C, Ciuciu P . Jointly Learning Non-Cartesian -Space Trajectories and Reconstruction Networks for 2D and 3D MR Imaging through Projection. Bioengineering (Basel). 2023; 10(2). PMC: 9952463. DOI: 10.3390/bioengineering10020158. View

4.
Nielsen J, Noll D . TOPPE: A framework for rapid prototyping of MR pulse sequences. Magn Reson Med. 2017; 79(6):3128-3134. PMC: 6134833. DOI: 10.1002/mrm.26990. View

5.
Gurney P, Hargreaves B, Nishimura D . Design and analysis of a practical 3D cones trajectory. Magn Reson Med. 2006; 55(3):575-82. DOI: 10.1002/mrm.20796. View