» Articles » PMID: 36937683

Evaluation of T2-prepared Blood Oxygenation Level Dependent Functional Magnetic Resonance Imaging with an Event-related Task: Hemodynamic Response Function and Reproducibility

Overview
Journal Front Neurosci
Date 2023 Mar 20
PMID 36937683
Authors
Affiliations
Soon will be listed here.
Abstract

T2-prepared (T2prep) blood oxygenation level dependent (BOLD) functional MRI (fMRI) is an alternative fMRI approach developed to mitigate the susceptibility artifacts that are typically observed in brain regions near air-filled cavities, bleeding and calcification, and metallic objects in echo-planar-imaging (EPI) based fMRI images. Here, T2prep BOLD fMRI was evaluated in an event-related paradigm for the first time. Functional experiments were performed using gradient-echo (GRE) EPI, spin-echo (SE) EPI, and T2prep BOLD fMRI during an event-related visual task in 10 healthy human subjects. Each fMRI method was performed with a low (3.4 × 3.4 × 4 mm) and a high (1.5 mm isotropic) spatial resolution on 3T and a high resolution (1.5 mm isotropic) on 7T. Robust activation were detected in the visual cortex with all three fMRI methods. In each group of fMRI scans (3T low resolution, 3T high resolution, and 7T high resolution), GRE EPI showed the highest signal change (ΔS/S), largest full-width-at-half-maximum (FWHM) and longest time-to-peak (TTP) extracted from the hemodynamic response functions (HRF), indicating substantial signal contribution from large draining veins which have longer response times than microvessels. In contrast, T2prep BOLD showed the lowest ΔS/S, smallest FWHM, and shortest TTP, suggesting that T2prep BOLD may have a purer T2-weighted BOLD contrast that is more sensitive to microvessels compared to GRE/SE EPI BOLD. This trend was more obvious in fMRI scans performed with a lower spatial resolution on a lower field (3T with a 3.4 × 3.4 × 4 mm voxel). Scan-rescan reproducibility in the same subjects was comparable among the three fMRI methods. The results from the current study are expected to be useful to establish T2prep BOLD as a useful alternative fMRI approach for event-related fMRI in brain regions with large susceptibility artifacts.

References
1.
Schar M, Kozerke S, Fischer S, Boesiger P . Cardiac SSFP imaging at 3 Tesla. Magn Reson Med. 2004; 51(4):799-806. DOI: 10.1002/mrm.20024. View

2.
Landman B, Huang A, Gifford A, Vikram D, Lim I, Farrell J . Multi-parametric neuroimaging reproducibility: a 3-T resource study. Neuroimage. 2010; 54(4):2854-66. PMC: 3020263. DOI: 10.1016/j.neuroimage.2010.11.047. View

3.
Burock M, Buckner R, Woldorff M, Rosen B, Dale A . Randomized event-related experimental designs allow for extremely rapid presentation rates using functional MRI. Neuroreport. 1998; 9(16):3735-9. DOI: 10.1097/00001756-199811160-00030. View

4.
Duong T, Yacoub E, Adriany G, Hu X, Ugurbil K, Kim S . Microvascular BOLD contribution at 4 and 7 T in the human brain: gradient-echo and spin-echo fMRI with suppression of blood effects. Magn Reson Med. 2003; 49(6):1019-27. DOI: 10.1002/mrm.10472. View

5.
Cheng Y, van Zijl P, Hua J . Measurement of parenchymal extravascular R2* and tissue oxygen extraction fraction using multi-echo vascular space occupancy MRI at 7 T. NMR Biomed. 2014; 28(2):264-71. PMC: 4297270. DOI: 10.1002/nbm.3250. View