» Articles » PMID: 36877178

Accurate Post-Calibration Predictions for Noninvasive Glucose Measurements in People Using Confocal Raman Spectroscopy

Abstract

In diabetes prevention and care, invasiveness of glucose measurement impedes efficient therapy and hampers the identification of people at risk. Lack of calibration stability in non-invasive technology has confined the field to short-term proof of principle. Addressing this challenge, we demonstrate the first practical use of a Raman-based and portable non-invasive glucose monitoring device used for at least 15 days following calibration. In a home-based clinical study involving 160 subjects with diabetes, the largest of its kind to our knowledge, we find that the measurement accuracy is insensitive to age, sex, and skin color. A subset of subjects with type 2 diabetes highlights promising real-life results with 99.8% of measurements within A + B zones in the consensus error grid and a mean absolute relative difference of 14.3%. By overcoming the problem of calibration stability, we remove the lingering uncertainty about the practical use of non-invasive glucose monitoring, boding a new, non-invasive era in diabetes monitoring.

Citing Articles

Clinical evaluation of a polarization-based optical noninvasive glucose sensing system.

Leung H, Gong C, Geiser L, Fivekiller E, Bui N, Vu T Sci Rep. 2025; 15(1):8877.

PMID: 40087308 DOI: 10.1038/s41598-025-92515-6.


Subcutaneous depth-selective spectral imaging with mμSORS enables noninvasive glucose monitoring.

Zhang Y, Zhang L, Wang L, Shao S, Tao B, Hu C Nat Metab. 2025; 7(2):421-433.

PMID: 39910379 DOI: 10.1038/s42255-025-01217-w.


Flexible Non-Enzymatic Glucose Sensors: One-Step Green Synthesis of NiO Nanoporous Films via an Electro-Exploding Wire Technique.

Ahamad N, Banerjee S, Wei C, Lu K, Khedulkar A, Jian W ACS Appl Mater Interfaces. 2024; 16(47):64494-64504.

PMID: 39531442 PMC: 11615849. DOI: 10.1021/acsami.4c13653.


Accuracy enhancement of metabolic index-based blood glucose estimation with a screening process for low-quality data.

Nakazawa T, Morishita K, Ienaka A, Fujii T, Ito M, Matsushita F J Biomed Opt. 2024; 29(10):107001.

PMID: 39464244 PMC: 11503645. DOI: 10.1117/1.JBO.29.10.107001.


Highly Sensitive Perovskite Photoplethysmography Sensor for Blood Glucose Sensing Using Machine Learning Techniques.

Zheng Y, Zhan Z, Chen Q, Chen J, Luo J, Cai J Adv Sci (Weinh). 2024; 11(43):e2405681.

PMID: 39303203 PMC: 11578317. DOI: 10.1002/advs.202405681.


References
1.
Hanna J, Bteich M, Tawk Y, Ramadan A, Dia B, Asadallah F . Noninvasive, wearable, and tunable electromagnetic multisensing system for continuous glucose monitoring, mimicking vasculature anatomy. Sci Adv. 2020; 6(24):eaba5320. PMC: 7286677. DOI: 10.1126/sciadv.aba5320. View

2.
Rebrin K, Steil G . Can interstitial glucose assessment replace blood glucose measurements?. Diabetes Technol Ther. 2001; 2(3):461-72. DOI: 10.1089/15209150050194332. View

3.
Teymourian H, Barfidokht A, Wang J . Electrochemical glucose sensors in diabetes management: an updated review (2010-2020). Chem Soc Rev. 2020; 49(21):7671-7709. DOI: 10.1039/d0cs00304b. View

4.
Barman I, Kong C, Singh G, Dasari R, Feld M . Accurate spectroscopic calibration for noninvasive glucose monitoring by modeling the physiological glucose dynamics. Anal Chem. 2010; 82(14):6104-14. PMC: 2915589. DOI: 10.1021/ac100810e. View

5.
Rodbard D . Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities. Diabetes Technol Ther. 2016; 18 Suppl 2:S3-S13. PMC: 4717493. DOI: 10.1089/dia.2015.0417. View