» Articles » PMID: 36844110

Placenta Accreta Spectrum and Hysterectomy Prediction Using MRI Radiomic Features

Abstract

In women with placenta accreta spectrum (PAS), patient management may involve cesarean hysterectomy at delivery. Magnetic resonance imaging (MRI) has been used for further evaluation of PAS and surgical planning. This work tackles two prediction problems: predicting presence of PAS and predicting hysterectomy using MR images of pregnant patients. First, we extracted approximately 2,500 radiomic features from MR images with two regions of interest: the placenta and the uterus. In addition to analyzing two regions of interest, we dilated the placenta and uterus masks by 5, 10, 15, and 20 mm to gain insights from the myometrium, where the uterus and placenta overlap in the case of PAS. This study cohort includes 241 pregnant women. Of these women, 89 underwent hysterectomy while 152 did not; 141 with suspected PAS, and 100 without suspected PAS. We obtained an accuracy of 0.88 for predicting hysterectomy and an accuracy of 0.92 for classifying suspected PAS. The radiomic analysis tool is further validated, it can be useful for aiding clinicians in decision making on the care of pregnant women.

Citing Articles

Machine learning applications in placenta accreta spectrum disorders.

Danaei M, Yeganegi M, Azizi S, Jayervand F, Shams S, Sharifi M Eur J Obstet Gynecol Reprod Biol X. 2025; 25():100362.

PMID: 39845985 PMC: 11751428. DOI: 10.1016/j.eurox.2024.100362.


Radiomic study of antenatal prediction of severe placenta accreta spectrum from MRI.

Bartels H, Wolsztynski E, ODoherty J, Brophy D, MacDermott R, Atallah D Br J Radiol. 2024; 97(1163):1833-1842.

PMID: 39152998 PMC: 11491593. DOI: 10.1093/bjr/tqae164.


Risk factors of emergency cesarean section in pregnant women with severe placenta accreta spectrum: a retrospective cohort study.

Zhao H, Li X, Yang S, Liu T, Zhan J, Zou J Front Med (Lausanne). 2023; 10:1195546.

PMID: 37502363 PMC: 10370267. DOI: 10.3389/fmed.2023.1195546.

References
1.
Afshar Y, Dong J, Zhao P, Li L, Wang S, Zhang R . Circulating trophoblast cell clusters for early detection of placenta accreta spectrum disorders. Nat Commun. 2021; 12(1):4408. PMC: 8333096. DOI: 10.1038/s41467-021-24627-2. View

2.
Jauniaux E, Kingdom J, Silver R . A comparison of recent guidelines in the diagnosis and management of placenta accreta spectrum disorders. Best Pract Res Clin Obstet Gynaecol. 2020; 72:102-116. DOI: 10.1016/j.bpobgyn.2020.06.007. View

3.
Shao Q, Xuan R, Wang Y, Xu J, Ouyang M, Yin C . Deep learning and radiomics analysis for prediction of placenta invasion based on T2WI. Math Biosci Eng. 2021; 18(5):6198-6215. DOI: 10.3934/mbe.2021310. View

4.
Yip S, Aerts H . Applications and limitations of radiomics. Phys Med Biol. 2016; 61(13):R150-66. PMC: 4927328. DOI: 10.1088/0031-9155/61/13/R150. View

5.
Shahedi M, Dormer J, T T A, Do Q, Xi Y, Lewis M . Segmentation of uterus and placenta in MR images using a fully convolutional neural network. Proc SPIE Int Soc Opt Eng. 2020; 11314. PMC: 7261604. DOI: 10.1117/12.2549873. View