» Articles » PMID: 36836710

Robotic Bronchoscopy: Review of Three Systems

Overview
Journal Life (Basel)
Specialty Biology
Date 2023 Feb 25
PMID 36836710
Authors
Affiliations
Soon will be listed here.
Abstract

Robotic bronchoscopy (RB) has been shown to improve access to smaller and more peripheral lung lesions, while simultaneously staging the mediastinum. Pre-clinical studies demonstrated extremely high diagnostic yields, but real-world RB yields have yet to fully matched up in prospective studies. Despite this, RB technology has rapidly evolved and has great potential for lung-cancer diagnosis and even treatment. In this article, we review the historical and present challenges with RB in order to compare three RB systems.

Citing Articles

Outcomes of Robot-Assisted Transbronchial Biopsies of Pulmonary Nodules: A Review.

Ebeling P, Daouk S, Keddissi J, Youness H Diagnostics (Basel). 2025; 15(4).

PMID: 40002601 PMC: 11854533. DOI: 10.3390/diagnostics15040450.


Dual robotic surgery: Da Vinci SP and Levita MARS (magnetic-assisted robotic surgery) platforms.

Gonzalez A, Eilender B, Cadeddu J J Robot Surg. 2025; 19(1):70.

PMID: 39945921 DOI: 10.1007/s11701-025-02231-6.


Assessing the accuracy of a multisection robotic bronchoscope prototype in localization and targeting of small pulmonary lesions.

Beqari J, Hurd J, Masaki F, Tfayli B, Kharroubi H, Naito M JTCVS Tech. 2024; 26:112-120.

PMID: 39156546 PMC: 11329203. DOI: 10.1016/j.xjtc.2024.05.011.


Review on endobronchial therapies-current status and future.

Chan J, Siu I, Chang A, Li M, Lau R, Mok T Ann Transl Med. 2024; 12(4):75.

PMID: 39118957 PMC: 11304415. DOI: 10.21037/atm-23-1430.


Diagnostic utility of adding needle aspiration (using PeriView FLEX needle) to radial endobronchial ultrasound guide sheath transbronchial lung biopsy: a single center retrospective study.

Lee D, Chae G, Kim J, Ra S, Seo K, Jegal Y J Thorac Dis. 2024; 16(6):3818-3827.

PMID: 38983157 PMC: 11228739. DOI: 10.21037/jtd-23-1598.


References
1.
Kalchiem-Dekel O, Fuentes P, Bott M, Beattie J, Lee R, Chawla M . Multiplanar 3D fluoroscopy redefines tool-lesion relationship during robotic-assisted bronchoscopy. Respirology. 2020; 26(1):120-123. DOI: 10.1111/resp.13966. View

2.
Gould M, Donington J, Lynch W, Mazzone P, Midthun D, Naidich D . Evaluation of individuals with pulmonary nodules: when is it lung cancer? Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013; 143(5 Suppl):e93S-e120S. PMC: 3749714. DOI: 10.1378/chest.12-2351. View

3.
Fielding D, Bashirzadeh F, Son J, Todman M, Chin A, Tan L . First Human Use of a New Robotic-Assisted Fiber Optic Sensing Navigation System for Small Peripheral Pulmonary Nodules. Respiration. 2019; 98(2):142-150. DOI: 10.1159/000498951. View

4.
Thiboutot J, Argento A, Akulian J, Lee H, DeMaio A, Kapp C . Accuracy of Pulmonary Nodule Sampling Using Robotic Assisted Bronchoscopy with Shape Sensing, Fluoroscopy, and Radial Endobronchial Ultrasound (The ACCURACY Study). Respiration. 2022; 101(5):485-493. DOI: 10.1159/000522514. View

5.
Rai H, Graham E, Ghoshal A, McDill H, Hassan M, Nicholson T . Endobronchial Ultrasound-guided Sampling of Centrally Located Intrapulmonary Tumors Provides Suitable Material for Diagnostic and Molecular Testing. J Bronchology Interv Pulmonol. 2022; 30(2):163-168. DOI: 10.1097/LBR.0000000000000895. View