» Articles » PMID: 36795007

Multimodality CT Imaging Contributes to Improving the Diagnostic Accuracy of Solitary Pulmonary Nodules: a Multi-institutional and Prospective Study

Overview
Journal Radiol Oncol
Publisher Sciendo
Specialties Oncology
Radiology
Date 2023 Feb 16
PMID 36795007
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Solitary pulmonary nodules (SPNs) are one of the most common chest computed tomography (CT) abnormalities clinically. We aimed to investigate the value of non-contrast enhanced CT (NECT), contrast enhanced CT (CECT), CT perfusion imaging (CTPI), and dual- energy CT (DECT) used for differentiating benign and malignant SPNs with a multi-institutional and prospective study.

Patients And Methods: Patients with 285 SPNs were scanned with NECT, CECT, CTPI and DECT. Differences between the benign and malignant SPNs on NECT, CECT, CTPI, and DECT used separately (NECT combined with CECT, DECT, and CTPI were methods of A, B, and C) or in combination (Method A + B, A + C, B + C, and A + B + C) were compared by receiver operating characteristic curve analysis.

Results: Multimodality CT imaging showed higher performances (sensitivities of 92.81% to 97.60%, specificities of 74.58% to 88.14%, and accuracies of 86.32% to 93.68%) than those of single modality CT imaging (sensitivities of 83.23% to 85.63%, specificities of 63.56% to 67.80%, and accuracies of 75.09% to 78.25%, all < 0.05).

Conclusions: SPNs evaluated with multimodality CT imaging contributes to improving the diagnostic accuracy of benign and malignant SPNs. NECT helps to locate and evaluate the morphological characteristics of SPNs. CECT helps to evaluate the vascularity of SPNs. CTPI using parameter of permeability surface and DECT using parameter of normalized iodine concentration at the venous phase both are helpful for improving the diagnostic performance.

Citing Articles

Diagnostic accuracy of low-dose dual-input computed tomography perfusion in the differential diagnosis of pulmonary benign and malignant ground-glass nodules.

Hu X, Gou J, Wang L, Lin W, Li W, Yang F Sci Rep. 2024; 14(1):17098.

PMID: 39048627 PMC: 11269666. DOI: 10.1038/s41598-024-68143-x.


Thoracic Diseases: Technique and Applications of Dual-Energy CT.

Perrella A, Bagnacci G, Di Meglio N, Di Martino V, Mazzei M Diagnostics (Basel). 2023; 13(14).

PMID: 37510184 PMC: 10378112. DOI: 10.3390/diagnostics13142440.

References
1.
Borghesi A, Michelini S, Nocivelli G, Silva M, Scrimieri A, Pezzotti S . Solid Indeterminate Pulmonary Nodules Less Than or Equal to 250 mm: Application of the Updated Fleischner Society Guidelines in Clinical Practice. Radiol Res Pract. 2019; 2019:7218258. PMC: 6335705. DOI: 10.1155/2019/7218258. View

2.
Gould M, Donington J, Lynch W, Mazzone P, Midthun D, Naidich D . Evaluation of individuals with pulmonary nodules: when is it lung cancer? Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013; 143(5 Suppl):e93S-e120S. PMC: 3749714. DOI: 10.1378/chest.12-2351. View

3.
McDonald J, Koo C, White D, Hartman T, Bender C, Sykes A . Addition of the Fleischner Society Guidelines to Chest CT Examination Interpretive Reports Improves Adherence to Recommended Follow-up Care for Incidental Pulmonary Nodules. Acad Radiol. 2016; 24(3):337-344. PMC: 5309169. DOI: 10.1016/j.acra.2016.08.026. View

4.
Wen Q, Yue Y, Shang J, Lu X, Gao L, Hou Y . The application of dual-layer spectral detector computed tomography in solitary pulmonary nodule identification. Quant Imaging Med Surg. 2021; 11(2):521-532. PMC: 7779913. DOI: 10.21037/qims-20-2. View

5.
Swensen S, Viggiano R, Midthun D, Muller N, Sherrick A, Yamashita K . Lung nodule enhancement at CT: multicenter study. Radiology. 2000; 214(1):73-80. DOI: 10.1148/radiology.214.1.r00ja1473. View