» Articles » PMID: 30195416

Combination of Adaptive Statistical Iterative Reconstruction-V and Lower Tube Voltage During Craniocervical Computed Tomographic Angiography Yields Better Image Quality with a Reduced Radiation Dose

Overview
Journal Acad Radiol
Specialty Radiology
Date 2018 Sep 10
PMID 30195416
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Rationale And Objectives: To evaluate image quality and radiation exposure when using the adaptive statistical iterative reconstruction-V (ASIR-V) algorithm for reconstructing craniocervical computed tomographic angiography images acquired at 100 kVp.

Materials And Methods: We randomly divided 121 patients into three groups: group A (conventional protocol), 120 kVp with filtered back projection; group B, 120 kVp with 50% ASIR-V; and group C, 100 kVp with 50% ASIR-V. All patients underwent scans in a 256-slice computed tomography (CT) scanner. Radiation dose (volume CT dose index), dose-length product, and effective dose, objective parameters such as arterial attenuation value, signal-to-noise ratio, contrast-to-noise ratio, and noise obtained at head, neck, and shoulder levels were compared among the groups. Subjective image quality was independently assessed by two radiologists, and interobserver reliability was assessed using kappa analysis.

Results: The radiation dose in group C was the lowest (p < 0.01) with a 40% reduction in volume CT dose index, dose-length product, and effective dose values compared to group A, and group C showed higher arterial attenuation than either group A or B (p < 0.01). Additionally, signal-to-noise ratio and contrast-to-noise ratio were higher and noise was lower in groups B and C than group A. Group C had better subjective image quality than groups A and B (p < 0.05), and the interobserver reliability between the two radiologists was high (k = 0.783).

Conclusion: Compared to the conventional protocol, using 50% ASIR-V and the 100 kVp protocol during craniocervical computed tomographic angiography yields better objective and subjective image quality at lower radiation doses.

Citing Articles

The application value of a vendor-specific deep learning image reconstruction algorithm in "triple low" head and neck computed tomography angiography.

Zhang Q, Lin Y, Zhang H, Ding J, Pan J, Zhang S Quant Imaging Med Surg. 2024; 14(4):2955-2967.

PMID: 38617163 PMC: 11007512. DOI: 10.21037/qims-23-1602.


Effect of Low Tube Voltage (100 kV) Combined with ASIR-V on the Visualization and Image Quality of the Adamkiewicz Artery: A Comparison with 120 kV Protocol.

Deng J, Ma T, Yan J, Wu S, Yan G, Li H Diagnostics (Basel). 2023; 13(15).

PMID: 37568857 PMC: 10417362. DOI: 10.3390/diagnostics13152495.


Computed Tomography of the Head : A Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose.

Dieckmeyer M, Sollmann N, Kupfer K, Loffler M, Paprottka K, Kirschke J Clin Neuroradiol. 2023; 33(3):591-610.

PMID: 36862232 PMC: 10449676. DOI: 10.1007/s00062-023-01271-5.


Multimodality CT imaging contributes to improving the diagnostic accuracy of solitary pulmonary nodules: a multi-institutional and prospective study.

Yan G, Li H, Fan X, Deng J, Yan J, Qiao F Radiol Oncol. 2023; 57(1):20-34.

PMID: 36795007 PMC: 10039475. DOI: 10.2478/raon-2023-0008.


Application of multiple injections of contrast agent in head and neck CT arteriovenous angiography in children: Study protocol clinical trial (SPIRIT Compliant).

Tang S, Zhang G, Chen Z, Liu X, Fan X, Liu D Medicine (Baltimore). 2020; 99(15):e19773.

PMID: 32282739 PMC: 7220194. DOI: 10.1097/MD.0000000000019773.