» Articles » PMID: 36735263

Epicardial Vs. Transvenous Implantable Cardioverter Defibrillators in Children

Abstract

Aims: The implantable cardioverter defibrillator (ICD) has been increasingly used in children. Both epicardial and transvenous approaches are used, with controversy regarding the best option with no specific recommendations. We aimed to compare outcomes associated with epicardial vs. transvenous ICDs in children.

Methods And Results: Data were analysed from a retrospective study including all patients <18-year-old implanted with an ICD in a tertiary centre from 2003 to 2021. Outcomes were compared between epicardial and transvenous ICDs. A total of 122 children with an ICD (mean age 11.5 ± 3.8 years, 57.4% males) were enrolled, with 84 (64.1%) epicardial ICDs and 38 (29.0%) transvenous ICDs. Early (<30 days) ICD-related complications were reported in 17 (20.2%) patients with an epicardial ICD vs. 0 (0.0%) with a transvenous ICD (P = 0.002). Over a mean follow-up of 4.8 ± 4.0 years, 25 (29.8%) patients with an epicardial ICD and 9 (23.7%) patients with a transvenous ICD experienced at least one late ICD-related complication [hazard ratio (HR) 1.8, 95% confidence interval (CI) 0.8-4.0]. Implantable cardioverter defibrillator lead dysfunction occurred in 19 (22.6%) patients with an epicardial ICD vs. 3 (7.9%) with a transvenous ICD (HR 5.7, 95% CI 1.3-24.5) and was associated with a higher incidence of ICD-related reintervention (HR 3.0, 95% CI 1.3-7.0). After considering potential confounders, especially age and weight at implantation, this association was no longer significant (P = 0.112). The freedom from ICD lead dysfunction was greater in patients with pleural coils than in those with epicardial coils (HR 0.38, 95% CI 0.15-0.96).

Conclusion: In children, after a consideration of patient characteristics at implantation, the burden of complications and ICD lead dysfunction appears to be similar in patients with epicardial and transvenous devices. Pleural coils seem to be associated with better outcomes than epicardial coils in this population.

Clinical Trial Registration: NCT05349162.

Citing Articles

Implantable cardioverter defibrillator therapy in paediatric patients for primary vs. secondary prevention.

Thuraiaiyah J, Philbert B, Jensen A, Xing L, Joergensen T, Lim C Europace. 2024; 26(9).

PMID: 39345160 PMC: 11440178. DOI: 10.1093/europace/euae245.


Congenital Long QT Syndrome in Children and Adolescents: A General Overview.

Balestra E, Bobbo M, Cittar M, Chicco D, DAgata Mottolese B, Barbi E Children (Basel). 2024; 11(5).

PMID: 38790576 PMC: 11119491. DOI: 10.3390/children11050582.


New Guidelines of Pediatric Cardiac Implantable Electronic Devices: What Is Changing in Clinical Practice?.

Silvetti M, Colonna D, Gabbarini F, Porcedda G, Rimini A, DOnofrio A J Cardiovasc Dev Dis. 2024; 11(4).

PMID: 38667717 PMC: 11050217. DOI: 10.3390/jcdd11040099.

References
1.
Stout K, Daniels C, Aboulhosn J, Bozkurt B, Broberg C, Colman J . 2018 AHA/ACC Guideline for the Management of Adults With Congenital Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. J Am Coll Cardiol. 2018; 73(12):e81-e192. DOI: 10.1016/j.jacc.2018.08.1029. View

2.
Pyngottu A, Werner H, Lehmann P, Balmer C . Health-Related Quality of Life and Psychological Adjustment of Children and Adolescents with Pacemakers and Implantable Cardioverter Defibrillators: A Systematic Review. Pediatr Cardiol. 2018; 40(1):1-16. DOI: 10.1007/s00246-018-2038-x. View

3.
Stiles M, Fauchier L, Morillo C, Wilkoff B . 2019 HRS/EHRA/APHRS/LAHRS focused update to 2015 expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. Heart Rhythm. 2019; 17(1):e220-e228. DOI: 10.1016/j.hrthm.2019.02.034. View

4.
von Elm E, Altman D, Egger M, Pocock S, Gotzsche P, Vandenbroucke J . Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. BMJ. 2007; 335(7624):806-8. PMC: 2034723. DOI: 10.1136/bmj.39335.541782.AD. View

5.
Jordan C, Freedenberg V, Wang Y, Curtis J, Gleva M, Berul C . Implant and clinical characteristics for pediatric and congenital heart patients in the national cardiovascular data registry implantable cardioverter defibrillator registry. Circ Arrhythm Electrophysiol. 2014; 7(6):1092-100. DOI: 10.1161/CIRCEP.114.001841. View