» Articles » PMID: 36718384

Analytical Sensitivity of COVID-19 Rapid Antigen Tests: A Case for a Robust Reference Standard

Overview
Journal Talanta Open
Specialty Chemistry
Date 2023 Jan 31
PMID 36718384
Authors
Affiliations
Soon will be listed here.
Abstract

Aggressive diagnostic testing remains an indispensable strategy for health and aged care facilities to prevent the transmission of SARS-CoV-2 in vulnerable populations. The preferred diagnostic platform has shifted towards COVID-19 rapid antigen tests (RATs) to identify the most infectious individuals. As such, RATs are being manufactured faster than at any other time in our history yet lack the relevant quantitative analytics required to inform on absolute analytical sensitivity enabling manufacturers to maintain high batch-to-batch reproducibility, and end-users to accurately compare brands for decision making. Here, we describe a novel reference standard to measure and compare the analytical sensitivity of RATs using a recombinant GFP-tagged nucleocapsid protein (NP-GFP). Importantly, we show that the GFP tag does not interfere with NP detection and provides several advantages affording streamlined protein expression and purification in high yields as well as faster, cheaper and more sensitive quality control measures for post-production assessment of protein solubility and stability. Ten commercial COVID-19 RATs were evaluated and ranked using NP-GFP as a reference standard. Analytical sensitivity data of the selected devices as determined with NP-GFP did not correlate with those reported by the manufacturers using the median tissue culture infectious dose (TCID) assay. Of note, TCID discordance has been previously reported. Taken together, our results highlight an urgent need for a reliable reference standard for evaluation and benchmarking of the analytical sensitivity of RAT devices. NP-GFP is a promising candidate as a reference standard that will ensure that RAT performance is accurately communicated to healthcare providers and the public.

Citing Articles

The Suitability of RNA from Positive SARS-CoV-2 Rapid Antigen Tests for Whole Virus Genome Sequencing and Variant Identification to Maintain Genomic Surveillance.

Cucina A, Contino F, Brunacci G, Orlando V, La Rocca M, Indelicato S Diagnostics (Basel). 2023; 13(24).

PMID: 38132202 PMC: 10742923. DOI: 10.3390/diagnostics13243618.

References
1.
Keiser P, Anantpadma M, Staples H, Carrion R, Davey R . Automation of Infectious Focus Assay for Determination of Filovirus Titers and Direct Comparison to Plaque and TCID Assays. Microorganisms. 2021; 9(1). PMC: 7826780. DOI: 10.3390/microorganisms9010156. View

2.
Kim D, Lee J, Yang J, Kim J, Kim V, Chang H . The Architecture of SARS-CoV-2 Transcriptome. Cell. 2020; 181(4):914-921.e10. PMC: 7179501. DOI: 10.1016/j.cell.2020.04.011. View

3.
Tahamtan A, Ardebili A . Real-time RT-PCR in COVID-19 detection: issues affecting the results. Expert Rev Mol Diagn. 2020; 20(5):453-454. PMC: 7189409. DOI: 10.1080/14737159.2020.1757437. View

4.
Nishiura H, Ito K, Anzai A, Kobayashi T, Piantham C, Rodriguez-Morales A . Relative Reproduction Number of SARS-CoV-2 Omicron (B.1.1.529) Compared with Delta Variant in South Africa. J Clin Med. 2022; 11(1). PMC: 8745053. DOI: 10.3390/jcm11010030. View

5.
Sniegowski J, Phail M, Wachter R . Maturation efficiency, trypsin sensitivity, and optical properties of Arg96, Glu222, and Gly67 variants of green fluorescent protein. Biochem Biophys Res Commun. 2005; 332(3):657-63. DOI: 10.1016/j.bbrc.2005.04.166. View