Rapid Detection of Hepatitis A Virus in Foods Using a Bioluminescent Assay in Real-Time (BART) and Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Technology
Overview
Microbiology
Nutritional Sciences
Affiliations
Foodborne hepatitis A infections have been considered as a major threat for public health worldwide. Increased incidences of hepatitis A virus (HAV) infection has been associated with growing global trade of food products. Rapid and sensitive detection of HAV in foods is very essential for investigating the outbreaks. Real-time RT-PCR has been most widely used for the detection of HAV by far. However, the technology relies on fluorescence determination of the amplicon and requires sophisticated, high-cost instruments and trained personnel, limiting its use in low resource settings. In this study, a robust, affordable, and simple assay, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay in combination with a bioluminescence-based determination of amplification in real-time (BART), was developed for the detection of HAV in different food matrices, including green onion, strawberry, mussel, and milk. The efficiencies of a one-step RT-LAMP-BART and a two-step RT-LAMP-BART were investigated for the detection of HAV in different food matrices and was compared with that of real-time RT-PCR. The sensitivity of the RT-LAMP-BART assay was significantly affected by Mg concentration (P < 0.05), in addition to primer quality. The optimal Mg concentration was 2 mM for one-step RT-LAMP-BART and 4 mM for two-step RT-LAMP-BART. Compared with cartridge-purified primers, HPLC-purified primers could greatly improve the sensitivity of the RT-LAMP-BART assay (P < 0.05). For detecting HAV in different food matrices, the performance of two-step RT-LAMP-BART was comparable with that of real-time RT-PCR and was better than that of one-step RT-LAMP-BART. The detection limit of the two-step RT-LAMP-BART for HAV in green onion, strawberry, mussel, and milk was 8.3 × 10 PFU/15 g, 8.3 × 10 PFU/50 g, 8.3 × 10 PFU/5 g, and 8.3 × 10 PFU/40 mL, respectively. The developed RT-LAMP-BART was an effective, simple, sensitive, and robust method for foodborne HAV detection.
Research Progress on Detection of Pathogens in Medical Wastewater by Electrochemical Biosensors.
Chen B, He J, Tian K, Qu J, Hong L, Lin Q Molecules. 2024; 29(15).
PMID: 39124939 PMC: 11314202. DOI: 10.3390/molecules29153534.
Point-of-Care Testing for Hepatitis Viruses: A Growing Need.
Pauly M, Ganova-Raeva L Life (Basel). 2023; 13(12).
PMID: 38137872 PMC: 10744957. DOI: 10.3390/life13122271.
Nemes K, Persson S, Simonsson M Viruses. 2023; 15(8).
PMID: 37632066 PMC: 10457876. DOI: 10.3390/v15081725.