» Articles » PMID: 36542239

Intra- and Inter-operator Variability in MRI-based Manual Segmentation of HCC Lesions and Its Impact on Dosimetry

Overview
Journal EJNMMI Phys
Specialty Radiology
Date 2022 Dec 21
PMID 36542239
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The aim was to quantify inter- and intra-observer variability in manually delineated hepatocellular carcinoma (HCC) lesion contours and the resulting impact on radioembolization (RE) dosimetry.

Methods: Ten patients with HCC lesions treated with Y-90 RE and imaged with post-therapy Y-90 PET/CT were selected for retrospective analysis. Three radiologists contoured 20 lesions manually on baseline multiphase contrast-enhanced MRIs, and two of the radiologists re-contoured at two additional sessions. Contours were transferred to co-registered PET/CT-based Y-90 dose maps. Volume-dependent recovery coefficients were applied for partial volume correction (PVC) when reporting mean absorbed dose. To understand how uncertainty varies with tumor size, we fit power models regressing relative uncertainty in volume and in mean absorbed dose on contour volume. Finally, we determined effects of segmentation uncertainty on tumor control probability (TCP), as calculated using logistic models developed in a previous RE study.

Results: The average lesion volume ranged from 1.8 to 194.5 mL, and the mean absorbed dose ranged from 23.4 to 1629.0 Gy. The mean inter-observer Dice coefficient for lesion contours was significantly less than the mean intra-observer Dice coefficient (0.79 vs. 0.85, p < 0.001). Uncertainty in segmented volume, as measured by the Coefficient of Variation (CV), ranged from 4.2 to 34.7% with an average of 17.2%. The CV in mean absorbed dose had an average value of 5.4% (range 1.2-13.1%) without PVC while it was 15.1% (range 1.5-55.2%) with PVC. Using the fitted models for uncertainty as a function of volume on our prior data, the mean change in TCP due to segmentation uncertainty alone was estimated as 16.2% (maximum 48.5%).

Conclusions: Though we find relatively high inter- and intra-observer reliability overall, uncertainty in tumor contouring propagates into non-negligible uncertainty in dose metrics and outcome prediction for individual cases that should be considered in dosimetry-guided treatment.

Citing Articles

Application of artificial intelligence in the diagnosis of hepatocellular carcinoma.

Koh B, Danpanichkul P, Wang M, Tan D, Ng C eGastroenterology. 2025; 1(2):e100002.

PMID: 39944000 PMC: 11770452. DOI: 10.1136/egastro-2023-100002.


Deep Learning-Powered CT-Less Multitracer Organ Segmentation From PET Images: A Solution for Unreliable CT Segmentation in PET/CT Imaging.

Salimi Y, Mansouri Z, Shiri I, Mainta I, Zaidi H Clin Nucl Med. 2025; 50(4):289-300.

PMID: 39883026 PMC: 11878580. DOI: 10.1097/RLU.0000000000005685.


A review of deep learning for brain tumor analysis in MRI.

Dorfner F, Patel J, Kalpathy-Cramer J, Gerstner E, Bridge C NPJ Precis Oncol. 2025; 9(1):2.

PMID: 39753730 PMC: 11698745. DOI: 10.1038/s41698-024-00789-2.


RIDGE: Reproducibility, Integrity, Dependability, Generalizability, and Efficiency Assessment of Medical Image Segmentation Models.

Maleki F, Moy L, Forghani R, Ghosh T, Ovens K, Langer S J Imaging Inform Med. 2024; .

PMID: 39557736 DOI: 10.1007/s10278-024-01282-9.


Exploring the Impact of Variability in Cell Segmentation and Tracking Approaches.

Wiggins L, OToole P, Brackenbury W, Wilson J Microsc Res Tech. 2024; 88(3):716-731.

PMID: 39548933 PMC: 11842944. DOI: 10.1002/jemt.24715.


References
1.
Gear J, Cox M, Gustafsson J, Sjogreen Gleisner K, Murray I, Glatting G . EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations. Eur J Nucl Med Mol Imaging. 2018; 45(13):2456-2474. PMC: 6208822. DOI: 10.1007/s00259-018-4136-7. View

2.
Mikell J, Kaza R, Roberson P, Younge K, Srinivasa R, Majdalany B . Impact of Y PET gradient-based tumor segmentation on voxel-level dosimetry in liver radioembolization. EJNMMI Phys. 2018; 5(1):31. PMC: 6265358. DOI: 10.1186/s40658-018-0230-y. View

3.
McErlean A, Panicek D, Zabor E, Moskowitz C, Bitar R, Motzer R . Intra- and interobserver variability in CT measurements in oncology. Radiology. 2013; 269(2):451-9. DOI: 10.1148/radiology.13122665. View

4.
Hatt M, Lee J, Schmidtlein C, El Naqa I, Caldwell C, De Bernardi E . Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211. Med Phys. 2017; 44(6):e1-e42. PMC: 5902038. DOI: 10.1002/mp.12124. View

5.