Uncertainty Propagation for SPECT/CT-based Renal Dosimetry in (177)Lu Peptide Receptor Radionuclide Therapy
Overview
Nuclear Medicine
Radiology
Authors
Affiliations
A computer model of a patient-specific clinical (177)Lu-DOTATATE therapy dosimetry system is constructed and used for investigating the variability of renal absorbed dose and biologically effective dose (BED) estimates. As patient models, three anthropomorphic computer phantoms coupled to a pharmacokinetic model of (177)Lu-DOTATATE are used. Aspects included in the dosimetry-process model are the gamma-camera calibration via measurement of the system sensitivity, selection of imaging time points, generation of mass-density maps from CT, SPECT imaging, volume-of-interest delineation, calculation of absorbed-dose rate via a combination of local energy deposition for electrons and Monte Carlo simulations of photons, curve fitting and integration to absorbed dose and BED. By introducing variabilities in these steps the combined uncertainty in the output quantity is determined. The importance of different sources of uncertainty is assessed by observing the decrease in standard deviation when removing a particular source. The obtained absorbed dose and BED standard deviations are approximately 6% and slightly higher if considering the root mean square error. The most important sources of variability are the compensation for partial volume effects via a recovery coefficient and the gamma-camera calibration via the system sensitivity.
Optimizing Cancer Treatment: Exploring the Role of AI in Radioimmunotherapy.
Azadinejad H, Farhadi Rad M, Shariftabrizi A, Rahmim A, Abdollahi H Diagnostics (Basel). 2025; 15(3).
PMID: 39941326 PMC: 11816985. DOI: 10.3390/diagnostics15030397.
On the reduction of imaging time-points for dosimetry in radionuclide therapy.
Gustafsson J, Taprogge J EJNMMI Phys. 2025; 12(1):14.
PMID: 39909959 PMC: 11799503. DOI: 10.1186/s40658-025-00721-y.
Activity quantification and dosimetry in radiopharmaceutical therapy with reference to Lutetium.
Ramonaheng K, Qebetu M, Ndlovu H, Swanepoel C, Smith L, Mdanda S Front Nucl Med. 2024; 4:1355912.
PMID: 39355215 PMC: 11440950. DOI: 10.3389/fnume.2024.1355912.
Pareto optimization of SPECT acquisition and reconstruction settings for Lu activity quantification.
Gustafsson J, Larsson E, Ljungberg M, Sjogreen Gleisner K EJNMMI Phys. 2024; 11(1):62.
PMID: 39004644 PMC: 11247071. DOI: 10.1186/s40658-024-00667-7.
Resch S, Takayama Fouladgar S, Zacherl M, Sheikh G, Liubchenko G, Rumiantcev M EJNMMI Phys. 2023; 10(1):11.
PMID: 36757516 PMC: 9911578. DOI: 10.1186/s40658-023-00529-8.