Adopted Walking Condition for Computational Simulation Approach on Bearing of Hip Joint Prosthesis: Review over the Past 30 Years

Overview
Journal Heliyon
Specialty Social Sciences
Date 2022 Dec 12
PMID 36506403
Authors
Affiliations
Soon will be listed here.
Abstract

Bearing on artificial hip joint experiences friction, wear, and surface damage that impact on overall performance and leading to failure at a particular time due to continuous contact that endangers the user. Assessing bearing hip joint using clinical study, experimental testing, and mathematical formula approach is challenging because there are some obstacles from each approach. Computational simulation is an effective alternative approach that is affordable, relatively fast, and more accessible than other approaches in examining various complex conditions requiring extensive resources and several different parameters. In particular, different gait cycles affect the sliding distance and distribution of gait loading acting on the joints. Appropriate selection and addition of gait cycles in computation modelling are crucial for accurate and reliable prediction and analysis of bearing performance such as wear a failure of implants. However, a wide spread of gait cycles and loading data are being considered and studied by researchers as reported in literature. The current article describes a comprehensive literature review adopted walking condition that has been carried out to study bearing using computational simulation approach over the past 30 years. Many knowledge gaps related to adoption procedures, simplification, and future research have been identified to obtain bearing analysis results with more realistic computational simulation approach according to physiological human hip joints.

Citing Articles

Integrating finite element analysis in total hip arthroplasty for childhood hip disorders: Enhancing precision and outcomes.

Ammarullah M World J Orthop. 2025; 16(1):98871.

PMID: 39850035 PMC: 11752482. DOI: 10.5312/wjo.v16.i1.98871.


Elbow stiffness due to malunited capitellum fracture: A case report and the role of 3D printing in surgical management.

Kholinne E, Gani K, Mitchel , William , Wonggokusuma E, Pribadi A Int J Surg Case Rep. 2024; 124:110398.

PMID: 39395254 PMC: 11562399. DOI: 10.1016/j.ijscr.2024.110398.


Investigation of contact behavior on a model of the dual-mobility artificial hip joint for Asians in different inner liner thicknesses.

Hidayat T, Ammarullah M, Ismail R, Saputra E, Lamura M, K N C World J Orthop. 2024; 15(4):321-336.

PMID: 38680676 PMC: 11045469. DOI: 10.5312/wjo.v15.i4.321.


Pulsed lavage in joint arthroplasty: A systematic review and meta-analysis.

Daher M, Haykal G, Aoun M, Moussallem M, Ghoul A, Tarchichi J World J Orthop. 2024; 15(3):293-301.

PMID: 38596185 PMC: 10999965. DOI: 10.5312/wjo.v15.i3.293.


Which approach of total hip arthroplasty is the best efficacy and least complication?.

Nitiwarangkul L, Hongku N, Pattanaprateep O, Rattanasiri S, Woratanarat P, Thakkinstian A World J Orthop. 2024; 15(1):73-93.

PMID: 38293261 PMC: 10824060. DOI: 10.5312/wjo.v15.i1.73.


References
1.
Ilesan R, Cordos C, Mihaila L, Flesar R, Popescu A, Perju-Dumbrava L . Proof of Concept in Artificial-Intelligence-Based Wearable Gait Monitoring for Parkinson's Disease Management Optimization. Biosensors (Basel). 2022; 12(4). PMC: 9027339. DOI: 10.3390/bios12040189. View

2.
Grabowy M, Wojteczko K, Wojteczko A, Wiazania G, Luszcz M, Ziabka M . Alumina-Toughened-Zirconia with Low Wear Rate in Ball-on-Flat Tribological Tests at Temperatures to 500 °C. Materials (Basel). 2021; 14(24). PMC: 8707460. DOI: 10.3390/ma14247646. View

3.
Alhossary A, Ang W, Chua K, Tay M, Ong P, Murakami T . Identification of Secondary Biomechanical Abnormalities in the Lower Limb Joints after Chronic Transtibial Amputation: A Proof-of-Concept Study Using SPM1D Analysis. Bioengineering (Basel). 2022; 9(7). PMC: 9311753. DOI: 10.3390/bioengineering9070293. View

4.
Vogel D, Klimek M, Saemann M, Bader R . Influence of the Acetabular Cup Material on the Shell Deformation and Strain Distribution in the Adjacent Bone-A Finite Element Analysis. Materials (Basel). 2020; 13(6). PMC: 7142599. DOI: 10.3390/ma13061372. View

5.
Wang L, Williams S, Udofia I, Isaac G, Fisher J, Jin Z . The effect of cup orientation and coverage on contact mechanics and range of motion of metal-on-metal hip resurfacing arthroplasty. Proc Inst Mech Eng H. 2012; 226(11):877-86. DOI: 10.1177/0954411912456926. View