Quantitative PCR (qPCR) is used for the determination of gene copy number (GCN). GCNs contribute to human disorders, and characterize copy number variation (CNV). The single laboratory method validations of duplex qPCR assays with hydrolysis probes on CYP21A1P and CYP21A2 genes, residing a CNV (RCCX CNV) and related to congenital adrenal hyperplasia, were performed using 46 human genomic DNA samples. We also performed the verifications on 5 qPCR assays for the genetic elements of RCCX CNV; C4A, C4B, CNV breakpoint, HERV-K(C4) CNV deletion and insertion alleles. Precision of each qPCR assay was under 1.01 CV%. Accuracy (relative error) ranged from 4.96±4.08% to 9.91±8.93%. Accuracy was not tightly linked to precision, but was significantly correlated with the efficiency of normalization using the RPPH1 internal reference gene (Spearman's ρ: 0.793-0.940, p>0.0001), ambiguity (ρ = 0.671, p = 0.029) and misclassification (ρ = 0.769, p = 0.009). A strong genomic matrix effect was observed, and target-singleplex (one target gene in one assay) qPCR was able to appropriately differentiate 2 GCN from 3 GCN at best. The analysis of all GCNs from the 7 qPCR assays using a multiplex approach increased the resolution of differentiation, and produced 98% of GCNs unambiguously, and all of which were in 100% concordance with GCNs measured by Southern blot, MLPA and aCGH. We conclude that the use of an internal (in one assay with the target gene) reference gene, the use of allele-specific primers or probes, and the multiplex approach (in one assay or different assays) are crucial for GCN determination using qPCR or other methods.

Citing Articles

The known structural variations in hearing loss and their diagnostic approaches: a comprehensive review.

Naghinejad M, Parvizpour S, Shekari Khaniani M, Mehri M, Mansoori Derakhshan S, Amirfiroozy A Mol Biol Rep. 2025; 52(1):131.

PMID: 39821465 DOI: 10.1007/s11033-025-10231-w.


Genomic complexity and clinical significance of the RCCX locus.

Shiryagin V, Devyatkin A, Fateev O, Petriaikina E, Bogdanov V, Antysheva Z PeerJ. 2024; 12:e18243.

PMID: 39512309 PMC: 11542561. DOI: 10.7717/peerj.18243.

References
1.
Conrad D, Pinto D, Redon R, Feuk L, Gokcumen O, Zhang Y . Origins and functional impact of copy number variation in the human genome. Nature. 2009; 464(7289):704-12. PMC: 3330748. DOI: 10.1038/nature08516. View

2.
Leung E, Agolini E, Pei X, Melis R, McMillin G, Friedman P . Validation of an Extensive CYP2D6 Assay Panel Based on Invader and TaqMan Copy Number Assays. J Appl Lab Med. 2020; 1(5):471-482. DOI: 10.1373/jalm.2016.021923. View

3.
Doleschall M, Luczay A, Koncz K, Hadzsiev K, Erhardt E, Szilagyi A . A unique haplotype of RCCX copy number variation: from the clinics of congenital adrenal hyperplasia to evolutionary genetics. Eur J Hum Genet. 2017; 25(6):702-710. PMC: 5477366. DOI: 10.1038/ejhg.2017.38. View

4.
El-Maouche D, Arlt W, Merke D . Congenital adrenal hyperplasia. Lancet. 2017; 390(10108):2194-2210. DOI: 10.1016/S0140-6736(17)31431-9. View

5.
Yao Y, Nellaker C, Karlsson H . Evaluation of minor groove binding probe and Taqman probe PCR assays: Influence of mismatches and template complexity on quantification. Mol Cell Probes. 2006; 20(5):311-6. DOI: 10.1016/j.mcp.2006.03.003. View