» Articles » PMID: 20041854

Comparison of Multiplex Ligation-dependent Probe Amplification and Real-time PCR Accuracy for Gene Copy Number Quantification Using the Beta-defensin Locus

Overview
Journal Biotechniques
Date 2010 Jan 1
PMID 20041854
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

The reliable quantification of gene copy number variations is a precondition for future investigations regarding their functional relevance. To date, there is no generally accepted gold standard method for copy number quantification, and methods in current use have given inconsistent results in selected cohorts. In this study, we compare two methods for copy number quantification. beta-defensin gene copy numbers were determined in parallel in 80 genomic DNA samples by real-time PCR and multiplex ligation-dependent probe amplification (MLPA). The pyrosequencing-based paralog ratio test (PPRT) was used as a standard of comparison in 79 out of 80 samples. Realtime PCR and MPLA results confirmed concordant DEFB4, DEFB103A, and DEFB104A copy numbers within samples. These two methods showed identical results in 32 out of 80 samples; 29 of these 32 samples comprised four or fewer copies. The coefficient of variation of MLPA is lower compared with PCR. In addition, the consistency between MLPA and PPRT is higher than either PCR/MLPA or PCR/PPRT consistency. In summary, these results suggest that MLPA is superior to real-time PCR in beta-defensin copy number quantification.

Citing Articles

Genomic complexity and clinical significance of the RCCX locus.

Shiryagin V, Devyatkin A, Fateev O, Petriaikina E, Bogdanov V, Antysheva Z PeerJ. 2024; 12:e18243.

PMID: 39512309 PMC: 11542561. DOI: 10.7717/peerj.18243.


Evaluation of the Copy Number Variants and Single-Nucleotide Polymorphisms of in Newborns with Respiratory Distress Syndrome-A Pilot Study.

Anciuc-Crauciuc M, Cucerea M, Crauciuc G, Tripon F, Banescu C Medicina (Kaunas). 2024; 60(3).

PMID: 38541145 PMC: 10972018. DOI: 10.3390/medicina60030419.


Quantitative PCR from human genomic DNA: The determination of gene copy numbers for congenital adrenal hyperplasia and RCCX copy number variation.

Doleschall M, Darvasi O, Herold Z, Doleschall Z, Nyiro G, Somogyi A PLoS One. 2022; 17(12):e0277299.

PMID: 36454796 PMC: 9714944. DOI: 10.1371/journal.pone.0277299.


Epidermal Growth Factor Receptor Variant III Mutation, an Emerging Molecular Marker in Glioblastoma Multiforme Patients: A Single Institution Study on the Indian Population.

Garima G, Thanvi S, Singh A, Verma V Cureus. 2022; 14(6):e26412.

PMID: 35911278 PMC: 9335135. DOI: 10.7759/cureus.26412.


Development and Evaluation of a Droplet Digital PCR Assay for 8p23 β-Defensin Cluster Copy Number Determination.

Wen T, Zhang X, Lippuner C, Schiff M, Stuber F Mol Diagn Ther. 2021; 25(5):607-615.

PMID: 34327613 PMC: 8320422. DOI: 10.1007/s40291-021-00546-2.