» Articles » PMID: 36378291

Functional Alignment with Robotic‑arm Assisted Total Knee Arthroplasty Demonstrated Better Patient-reported Outcomes Than Mechanical Alignment with Manual Total Knee Arthroplasty

Overview
Publisher Wiley
Date 2022 Nov 15
PMID 36378291
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Given the improved accuracy of robot-assisted surgery, robotic-arm assisted functionally aligned total knee arthroplasty (RFA-TKA) aims to preserve the native pre-arthritic knee biomechanics, to achieve balanced flexion-extension gaps. The purpose of this study was to compare the accuracy of the implant position and short-term clinical outcomes of patients who underwent RFA-TKA vs. mechanically aligned total knee arthroplasty with manual technique (MA-TKA).

Methods: A prospectively collected database was reviewed retrospectively for patients who underwent primary TKA. Sixty patients who underwent RFA-TKA between February 2020 and July 2020 were included in the RFA-TKA group. Sixty patients who underwent MA-TKA were included via 1:1 matching for age, sex, and body mass index based on the RFA-TKA group. For radiological evaluation, knee X-rays were used to assess the functional knee phenotype and implant position accuracy by measuring the coronal and sagittal alignment, and these measurements were compared between the two groups. Patient demographic characteristics and patient-reported outcomes including Knee Society scores, Western Ontario and McMaster Universities Arthritis Index, and forgotten joint score-12 were compared between the groups.

Results: Statistically significant differences were observed in postoperative 2-year clinical outcomes in favor of RFA-TKA group which showed greater accuracy in the tibial component sagittal alignment than MA-TKA (1.0 ± 2.3 vs. 0.7 ± 1.6, respectively; P < 0.001). However, outliers in the component positions were more common in the MA-TKA group, which was statistically significant for the femoral coronal and tibial sagittal alignments (P = 0.017 and 0.015, respectively).

Conclusions: Functional alignment in TKA could be accurately obtained with the assistance of a robotic arm, and the results showed greater 2 year postoperative patient-reported outcome and satisfaction than mechanically aligned TKA using manual instruments.

Level Of Evidence: III.

Citing Articles

Accuracy and clinical outcomes in total knee arthroplasty using an image-free navigation system.

Naito Y, Hasegawa M, Kobayashi G, Tone S, Sudo A Arch Orthop Trauma Surg. 2025; 145(1):190.

PMID: 40085222 DOI: 10.1007/s00402-025-05819-7.


Current developments in robotic assistance technology for total knee arthroplasty: a comprehensive overview.

Zhang H, Jiang X, Jin B, Zhang H, Liang J J Orthop Surg Res. 2025; 20(1):80.

PMID: 39844280 PMC: 11752961. DOI: 10.1186/s13018-025-05490-z.


Functional alignment is a feasible alignment strategy in robotic assisted total knee arthroplasty for knee osteoarthritis with extra-articular deformity - A case series.

Eu W, Ho J, Kunalan G SICOT J. 2025; 11():2.

PMID: 39803978 PMC: 11727079. DOI: 10.1051/sicotj/2024059.


[Digital tools in primary total knee arthroplasty-Prevalence in the German-speaking region].

Pohlig F, Becker R, Ettinger M, Calliess T, Hinterwimmer F, Tibesku C Orthopadie (Heidelb). 2024; 53(12):935-944.

PMID: 39485533 PMC: 11604827. DOI: 10.1007/s00132-024-04575-7.


A new gap balancing technique with functional alignment in total knee arthroplasty using the MAKO robotic arm system: a preliminary study.

Tsai H, Bao Z, Wu D, Han J, Jiang Q, Xu Z BMC Surg. 2024; 24(1):232.

PMID: 39143535 PMC: 11323490. DOI: 10.1186/s12893-024-02524-x.


References
1.
Agarwal N, To K, McDonnell S, Khan W . Clinical and Radiological Outcomes in Robotic-Assisted Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty. 2020; 35(11):3393-3409.e2. DOI: 10.1016/j.arth.2020.03.005. View

2.
Batailler C, Fernandez A, Swan J, Servien E, Haddad F, Catani F . MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc. 2020; 29(11):3585-3598. DOI: 10.1007/s00167-020-06283-z. View

3.
Begum F, Kayani B, Magan A, Chang J, Haddad F . Current concepts in total knee arthroplasty : mechanical, kinematic, anatomical, and functional alignment. Bone Jt Open. 2021; 2(6):397-404. PMC: 8244789. DOI: 10.1302/2633-1462.26.BJO-2020-0162.R1. View

4.
Bellemans J, Colyn W, Vandenneucker H, Victor J . The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2011; 470(1):45-53. PMC: 3237976. DOI: 10.1007/s11999-011-1936-5. View

5.
Chin B, Tan S, Chua K, Budiono G, Syn N, ONeill G . Robot-Assisted versus Conventional Total and Unicompartmental Knee Arthroplasty: A Meta-analysis of Radiological and Functional Outcomes. J Knee Surg. 2020; 34(10):1064-1075. DOI: 10.1055/s-0040-1701440. View