» Articles » PMID: 36359510

Visualization of Ray Propagation Through Extended Depth-of-Focus Intraocular Lenses

Overview
Specialty Radiology
Date 2022 Nov 11
PMID 36359510
Authors
Affiliations
Soon will be listed here.
Abstract

Extended depth-of-focus (EDoF) presbyopia-correcting intraocular lens (IOL) models differ in their optical design and performance. In the laboratory, we compared the ray propagation and light intensity profiles of four IOLs: the non-diffractive AcrySof IQ Vivity (Alcon Inc., Fort Worth, TX, USA) and two diffractive models, Symfony ZXR00 (Johnson & Johnson Vision, Jacksonville, FL, USA) and AT Lara 829 MP (Carl Zeiss Meditec, Berlin, Germany). A fourth lens, the monofocal AcrySof IQ SN60WF (Alcon Inc.) acted as the control. We projected a 520 nm laser light through each submerged lens in a bath of fluorescein solution. A camera mounted on a microscope captured the light that emerged from the IOL. We recorded the IOLs' point spread function (PSF) to determine the presence of unwanted visual effects. The ray propagation visualization and light intensity profile of the monofocal control showed one distinct focus, while the AcrySof IQ Vivity demonstrated an extended focus area. We observed two distinct foci with each diffractive IOL. We found a lower level of light spread beyond the PSF center for the AcrySof IQ Vivity compared to the diffractive IOLs. In conclusion, we could confirm the extended range of focus for all the EDoF IOL models. However, the non-diffractive AcrySof IQ Vivity appears to have a smoother transition from a far to an intermediate range. We discuss whether, in clinical use, the higher level of spurious light we found in the diffractive designs may translate into increased dysphotopsia.

Citing Articles

Functional Design Analysis of Two Current Extended-Depth-of-Focus Intraocular Lenses.

Mendroch D, Oberheide U, Altmeyer S Transl Vis Sci Technol. 2024; 13(8):33.

PMID: 39167376 PMC: 11343009. DOI: 10.1167/tvst.13.8.33.


[Overview of intraocular lenses with optics for correcting presbyopia].

Auffarth G, Labuz G, Khoramnia R, Yildirim T Ophthalmologie. 2024; 121(9):685-697.

PMID: 38980387 DOI: 10.1007/s00347-024-02071-z.


[Optical benchtop evaluation of special intraocular lens optics].

Labuz G, Khoramnia R, Naujokaitis T, Auffarth G Ophthalmologie. 2024; 121(9):698-705.

PMID: 38977490 DOI: 10.1007/s00347-024-02064-y.


Optical power profiles and aberrations of a non-diffractive wavefront-shaping extended depth of focus intraocular lens.

Garzon N, Gomez-Pedrero J, Albarran-Diego C, Fernandez-Nunez S, Villanueva Gomez-Chacon S, Garcia-Montero M Graefes Arch Clin Exp Ophthalmol. 2024; 262(9):2897-2906.

PMID: 38597962 PMC: 11377664. DOI: 10.1007/s00417-024-06469-y.


Refractive extended depth-of-focus lens design based on periodic power profile for presbyopia correction.

Lyu J, Bang S, Yoon G Ophthalmic Physiol Opt. 2023; 44(2):301-310.

PMID: 37984831 PMC: 10925839. DOI: 10.1111/opo.13253.

References
1.
Labuz G, Papadatou E, Khoramnia R, Auffarth G . Longitudinal Chromatic Aberration and Polychromatic Image Quality Metrics of Intraocular Lenses. J Refract Surg. 2018; 34(12):832-838. DOI: 10.3928/1081597X-20181108-01. View

2.
Kohnen T, Petermann K, Bohm M, Hemkeppler E, Ahmad W, Hinzelmann L . Nondiffractive wavefront-shaping extended depth-of-focus intraocular lens: visual performance and patient-reported outcomes. J Cataract Refract Surg. 2021; 48(2):144-150. DOI: 10.1097/j.jcrs.0000000000000826. View

3.
Reiss S, Forbrig J, Guthoff R, Terwee T, Stolz H, Siewert S . [Optimisation of the visualisation technique for optical paths through intraocular lenses for characterisation of multifocal imaging properties of Fresnel-zone plates]. Klin Monbl Augenheilkd. 2014; 231(12):1183-6. DOI: 10.1055/s-0034-1383300. View

4.
Chae S, Son H, Khoramnia R, Lee K, Choi C . Laboratory evaluation of the optical properties of two extended-depth-of-focus intraocular lenses. BMC Ophthalmol. 2020; 20(1):53. PMC: 7023787. DOI: 10.1186/s12886-020-1332-6. View

5.
Millan M, Vega F . Through-Focus Energy Efficiency and Longitudinal Chromatic Aberration of Three Presbyopia-Correcting Intraocular Lenses. Transl Vis Sci Technol. 2020; 9(12):13. PMC: 7674003. DOI: 10.1167/tvst.9.12.13. View