» Articles » PMID: 36264982

Magnetic Resonance Imaging Reveals Possible Cause of Diplopia After Baerveldt Glaucoma Implantation

Overview
Journal PLoS One
Date 2022 Oct 20
PMID 36264982
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To assess if ocular motility impairment, and the ensuing diplopia, after Baerveldt Glaucoma device (BGI) implantation, is related to the presence of a large fluid reservoir (bleb), using Magnetic Resonance Imaging (MRI).

Methods: In a masked observational study (CCMO-registry number: NL65633.058.18), the eyes of 30 glaucoma patients with (n = 12) or without diplopia (n = 18) who had previously undergone BGI implantation were scanned with a 7 Tesla MRI-scanner. The substructures of the BGI-complex, including both blebs and plate, were segmented in 3D. Primary outcomes were a comparison of volume and height of the BGI-complex between patients with and without diplopia. Comparisons were performed by using an unpaired t-test, Fisher's Exact or Mann-Whitney test. Correlations were determined by using Spearman correlation.

Results: The median volume and height of the BGI-complex was significantly higher in patients with compared to patients without diplopia (p = 0.007 and p = 0.025, respectively). Six patients had an excessively large total bleb volume (median of 1736.5mm3, interquartile range 1486.3-1933.9mm3), four of whom experienced diplopia (33% of the diplopia patients). Fibrotic strands through the BGI plate, intended to limit the height of the bleb, could be visualized but were not related to diplopia (75% versus 88%; p = 0.28).

Conclusions: With MRI, we show that in a significant number of diplopia cases a large bleb is present in the orbit. Given the large volume of these blebs, they are a likely explanation of the development of diplopia in at least some of the patients with diplopia after BGI implantation. Additionally, the MR-images confirm the presence of fibrotic strands. As these strands are also visible in patients with a large bleb, they are apparently not sufficient to restrict the bleb height.

Citing Articles

Magnetic Resonance Imaging in the Clinical Care for Uveal Melanoma Patients-A Systematic Review from an Ophthalmic Perspective.

Jaarsma-Coes M, Klaassen L, Marinkovic M, Luyten G, Vu T, Ferreira T Cancers (Basel). 2023; 15(11).

PMID: 37296958 PMC: 10252038. DOI: 10.3390/cancers15112995.

References
1.
Keene K, van Vught L, van de Velde N, Ciggaar I, Notting I, Genders S . The feasibility of quantitative MRI of extra-ocular muscles in myasthenia gravis and Graves' orbitopathy. NMR Biomed. 2020; 34(1):e4407. PMC: 7757175. DOI: 10.1002/nbm.4407. View

2.
Bailey A, Sarkisian Jr S . Complications of tube implants and their management. Curr Opin Ophthalmol. 2014; 25(2):148-53. DOI: 10.1097/ICU.0000000000000034. View

3.
Islamaj E, Jordaan-Kuip C, Vermeer K, Lemij H, de Waard P . Motility Changes and Diplopia After Baerveldt Glaucoma Drainage Device Implantation or After Trabeculectomy. Transl Vis Sci Technol. 2018; 7(5):7. PMC: 6136847. DOI: 10.1167/tvst.7.5.7. View

4.
Islamaj E, Wubbels R, de Waard P . Primary baerveldt versus trabeculectomy study after 5 years of follow-up. Acta Ophthalmol. 2019; 98(4):400-407. PMC: 7317510. DOI: 10.1111/aos.14265. View

5.
Jellema H, Baader A, Pitz S, Prick L, Wiersinga W, Mourits M . Comparison of cyclodeviation and duction measurement in Graves' orbitopathy patients using different devices. Strabismus. 2011; 19(2):43-51. DOI: 10.3109/09273972.2011.575435. View