Improved Patient Monitoring with a Novel Multisensory Smartwatch Application

Overview
Journal J Med Syst
Date 2022 Oct 19
PMID 36261739
Authors
Affiliations
Soon will be listed here.
Abstract

The design of medical alarms has been heavily criticized in the past decade. Auditory medical alarms have poor learnability, discernibility, and relevance, leading to poor patient outcomes, and alarm fatigue, and overall poor informatic system design. We developed a novel trimodal patient monitoring smartwatch application for patient monitoring. Participants completed two phases: (1) control and (2) our novel trimodal system while identifying alarms (heart rate, oxygenation, and blood pressure) and completing a cognitively demanding task. Alarms were auditory icons presented as either solo or co-alarms. Participant performance was assessed by accuracy and response time (RT) of alarm identification. Using the novel system, accuracy was significantly improved overall (p < 0.01) and in co-alarm situations (p < 0.01), but not for solo alarms (p = 0.484). RT was also significantly faster (p < 0.01) while using the novel system for all alarm types. Participants reported decreased mental workload using the novel system. This feasibility study shows that our novel alarm system performs better than current standards. Improvements in accuracy, RT and perceived mental workload indicate the potential of this system to have a positive impact on medical informatic systems and clinical monitoring, for both the patient and the clinician.

Citing Articles

Call for Decision Support for Electrocardiographic Alarm Administration Among Neonatal Intensive Care Unit Staff: Multicenter, Cross-Sectional Survey.

Tang X, Yang X, Yuan J, Yang J, Jin Q, Zhang H J Med Internet Res. 2024; 26():e60944.

PMID: 39705688 PMC: 11699503. DOI: 10.2196/60944.


Why Clinicians should Care about YouCare and Other Wearable Health Devices.

Padiyath A, Pratap J, Simpao A J Med Syst. 2024; 48(1):104.

PMID: 39546076 DOI: 10.1007/s10916-024-02123-6.


The effect of intelligent management interventions in intensive care units to reduce false alarms: An integrative review.

Li B, Yue L, Nie H, Cao Z, Chai X, Peng B Int J Nurs Sci. 2024; 11(1):133-142.

PMID: 38352290 PMC: 10859571. DOI: 10.1016/j.ijnss.2023.12.008.


A Spatiotemporal and Multisensory Approach to Designing Wearable Clinical ICU Alarms.

Sangari A, Bingham M, Cummins M, Sood A, Tong A, Purcell P J Med Syst. 2023; 47(1):105.

PMID: 37847469 DOI: 10.1007/s10916-023-01997-2.

References
1.
Burdick K, Jorgensen S, Combs T, Holmberg M, Kultgen S, Schlesinger J . SAVIOR ICU: sonification and vibrotactile interface for the operating room and intensive care unit. J Clin Monit Comput. 2019; 34(4):787-796. DOI: 10.1007/s10877-019-00381-1. View

2.
Schlesinger J, Baum Miller S, Nash K, Bruce M, Ashmead D, Shotwell M . Acoustic features of auditory medical alarms-An experimental study of alarm volume. J Acoust Soc Am. 2018; 143(6):3688. PMC: 6910025. DOI: 10.1121/1.5043396. View

3.
KIRCHNER W . Age differences in short-term retention of rapidly changing information. J Exp Psychol. 1958; 55(4):352-8. DOI: 10.1037/h0043688. View

4.
Schlesinger J, Stevenson R, Shotwell M, Wallace M . Improving pulse oximetry pitch perception with multisensory perceptual training. Anesth Analg. 2014; 118(6):1249-53. DOI: 10.1213/ANE.0000000000000222. View

5.
Edworthy J, Page R, Hibbard A, Kyle S, Ratnage P, Claydon S . Learning three sets of alarms for the same medical functions: a perspective on the difficulty of learning alarms specified in an international standard. Appl Ergon. 2013; 45(5):1291-6. DOI: 10.1016/j.apergo.2013.10.003. View