Purpose: This study aimed to develop a new 3D dual-echo rosette k-space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra-short transverse relaxation time (uT ) of brain was acquired to test the performance of the proposed UTE sequence.

Theory And Methods: The rosette trajectory was developed based on rotations of a "petal-like" pattern in the k -k plane, with oscillated extensions in the k -direction for 3D coverage. Five healthy volunteers underwent 10 dual-echo 3D rosette UTE scans with various TEs. Dual-exponential complex model fitting was performed on the magnitude data to separate uT signals, with the output of uT fraction, uT value, and long-T value.

Results: The 3D rosette dual-echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT fraction values than gray matter (10.9% ± 1.9% vs. 5.7% ± 2.4%). The uT value was approximately 0.10 ms in white matter .

Conclusion: The higher uT fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.

Citing Articles

Feasibility and comparison of 3D modified rosette ultra-short echo time (PETALUTE) with conventional weighted acquisition in P-MRSI.

Bozymski B, Shen X, Ozen A, Chiew M, Thomas M, Clarke W Sci Rep. 2025; 15(1):6465.

PMID: 39987281 PMC: 11846993. DOI: 10.1038/s41598-025-90630-y.


Are Collagen Protons Visible with the Zero Echo Time (ZTE) Magnetic Resonance Imaging Sequence: A DO Exchange and Freeze-Drying Study.

Guo T, Moazamian D, Suprana A, Jerban S, Chang E, Ma Y Bioengineering (Basel). 2025; 12(1).

PMID: 39851289 PMC: 11763331. DOI: 10.3390/bioengineering12010016.


Proton-free induction decay MRSI at 7 T in the human brain using an egg-shaped modified rosette K-space trajectory.

Blomer S, Hingerl L, Marjanska M, Bogner W, Motyka S, Hangel G Magn Reson Med. 2024; 93(4):1443-1457.

PMID: 39568225 PMC: 11782714. DOI: 10.1002/mrm.30368.


Two-parametric prescan calibration of gradient-induced sampling errors for rosette MRI.

Latta P, Jirik R, Vitous J, Macicek O, Vojtisek L, Rektor I Magn Reson Med. 2024; 93(3):1285-1297.

PMID: 39435570 PMC: 11680729. DOI: 10.1002/mrm.30355.


An accelerated PETALUTE MRI sequence for in vivo quantification of sodium content in human articular cartilage at 3T.

Villarreal C, Shen X, Alhulail A, Buffo N, Zhou X, Pogue E Skeletal Radiol. 2024; 54(3):601-610.

PMID: 39153083 PMC: 11769871. DOI: 10.1007/s00256-024-04774-5.


References
1.
Yablonskiy D, Sukstanskii A . Biophysical mechanisms of myelin-induced water frequency shifts. Magn Reson Med. 2014; 71(6):1956-8. PMC: 6366856. DOI: 10.1002/mrm.25214. View

2.
Weiskopf N, Lutti A, Helms G, Novak M, Ashburner J, Hutton C . Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT). Neuroimage. 2010; 54(3):2116-24. PMC: 3018573. DOI: 10.1016/j.neuroimage.2010.10.023. View

3.
Madio D, Lowe I . Ultra-fast imaging using low flip angles and FIDs. Magn Reson Med. 1995; 34(4):525-9. DOI: 10.1002/mrm.1910340407. View

4.
Noll D . Multishot rosette trajectories for spectrally selective MR imaging. IEEE Trans Med Imaging. 1997; 16(4):372-7. DOI: 10.1109/42.611345. View

5.
Stikov N, Boudreau M, Levesque I, Tardif C, Barral J, Pike G . On the accuracy of T1 mapping: searching for common ground. Magn Reson Med. 2014; 73(2):514-22. DOI: 10.1002/mrm.25135. View