Background and Objectives: The tibial component alignment is an important issue for the longevity of total knee arthroplasty (TKA). The purpose of our study was to investigate the usefulness of proximal tibial references determined by pre-operative radiography and intraoperative C-arm-guided hip and ankle center marking for the extramedullary guided tibial cut in mild (<10°) and severe (≥10°) varus knee TKA. Materials and Methods: A total of 150 consecutive patients (220 cases) who underwent total knee arthroplasty who were recruited from July 2011 to April 2017 were reviewed retrospectively. Before surgery, the proximal tibial reference point and medio-lateral cut thickness difference were identified. Then, hip and ankle centers were checked using a C-arm intensifier intraoperatively. The hip−knee−ankle (HKA) alignment and medial proximal tibial angle (MPTA) were assessed pre-operatively and post-operatively. More than 3° varus or valgus of HKA alignment or tibial component angle was defined as an outlier. Results: Mean follow-up duration was 26.9 months. Among 220 cases, 111 cases are classified as mild varus group and 109 cases are classified as severe varus group. The HKA alignment is significantly improved (p < 0.001). The average tibial component angle after surgery is 90.1°. A total of 21 cases (9.5%) and 3 cases (1.4%) are classified as outliers of HKA alignment and MPTA, respectively. Among MPTA outliers, one case is in the mild varus group and two cases are in the in severe varus group (p = 0.62). Conclusion: Measurement of proximal tibial radiographic references and checking the C-arm-guided intraoperative hip and ankle center could be helpful to obtain the favorable coronal position of the tibial component in the extramedullary guided tibial cut.

Citing Articles

Aseptic survival of the 1.5-stage exchange arthroplasty for periprosthetic joint infection was acceptable when using an autoclaved femoral component and a new polyethylene insert.

Song S, Hwang S, Baek H, Park C Knee Surg Sports Traumatol Arthrosc. 2023; 31(11):4996-5004.

PMID: 37640916 DOI: 10.1007/s00167-023-07552-3.


Effect of Combined Exercise Program on Lower Extremity Alignment and Knee Pain in Patients with Genu Varum.

Moon H, Seo Y, Kim W, Yu J, Lee H, Park Y Healthcare (Basel). 2023; 11(1).

PMID: 36611582 PMC: 9819428. DOI: 10.3390/healthcare11010122.

References
1.
Ritter M, Davis K, Meding J, Pierson J, Berend M, Malinzak R . The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011; 93(17):1588-96. DOI: 10.2106/JBJS.J.00772. View

2.
Vanlommel L, Vanlommel J, Claes S, Bellemans J . Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc. 2013; 21(10):2325-30. DOI: 10.1007/s00167-013-2481-4. View

3.
Piovan G, Farinelli L, Screpis D, Iacono V, Povegliano L, Bonomo M . Distal femoral osteotomy versus lateral unicompartmental arthroplasty for isolated lateral tibiofemoral osteoarthritis with intra-articular and extra-articular deformity: a propensity score-matched analysis. Knee Surg Relat Res. 2022; 34(1):34. PMC: 9290203. DOI: 10.1186/s43019-022-00164-0. View

4.
Lee S, Kwon K, Lee Y, Moon Y . Navigation-Assisted Total Knee Arthroplasty for a Valgus Knee Improves Limb and Femoral Component Alignment. Orthopedics. 2019; 42(2):e253-e259. DOI: 10.3928/01477447-20190211-02. View

5.
Liu H, Shang P, Ying X, Zhang Y . Shorter survival rate in varus-aligned knees after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2015; 24(8):2663-71. DOI: 10.1007/s00167-015-3781-7. View